Запчасти и компоненты для торгового оборудования. Более 8 500 клиентов и более 1 000 000 товаров! Скрыть
Сортировать по: Название   Цена  
Каталожный номер: 261308
Supply
Rated voltage7.2 V DC , battery operated
Electrical specifications
Output rated operating current4 ... 20 mA
Supplyloop power for field devices
voltage 8 ... 23 V DC, adjustable in steps of 0.1 V
Input
Suitable field devicesusable for:
- one point-to-point connection with a HART field device, or
- one point-to-point connection with a 4 ... 20 mA field device, or
- up to four externally powered HART field devices operating in multidrop mode
Connectionterminals 1, 2, 3, 4, 5, 6
multiple wirings available , depending on operating mode
Current4 ... 20 mA
HART communication
ProtocolHART 7.3, backward compatible
Number of devices- one passive 4 ... 20 mA/HART field device
- up to 4 HART field devices in multidrop mode
Transfer rate1200 Bit/s
Parametersprimary/secondary master, preambles, retries and short address scan ranges
Output
Output variablesPV: loop current
SV, TV, QV:configurable according to user requirement
- adapter: temperature, battery voltage, energy consumed and estimated battery life-time
- 4 ... 20 mA device: scaled or linearized process value
- HART device: up to four process variables
Transfer characteristics
Accuracycurrent input: 0.125 % of measuring range
Influence of ambient temperaturecurrent input: 5 µA/K
Indicators/settings
Parameter assignment- wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP)
- device variables mapping
- publishing of up to ten burst messages in a wireless network, period and trigger mode selectable
- notification of up to five events from adapter and/or connected device(s) in a wireless network
- scaling and linearization of 4 ... 20 mA signal of connected analog device
- tuning of supply parameters for the connected device
- locking/unlocking of device parameterization
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013, CLASS A
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 2014/53/EUEN 300328 V2.1.1:2017 , EN 301489-17 V3.1.1:2017 , EN 301489-1 V2.1.1:2017
FCC CFR47 Part 15 B and CANSI C63.4-2003
RoHs
Directive 2011/65/EU (RoHS)EN 50581:2012
Conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Vibration resistance20 ... 2000 Hz, 0,01 g2/Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
test setup and execution acc. to EN 60068-2-60
Mechanical specifications
Degree of protectionIP66
MaterialAluminum
Massapprox. 1000 g
Dimensions92 x 89.5 x 92.8 mm (without cable glands and antenna)
Mountingmounting on field device , panel or pole mounting
Data for application in connection with hazardous areas
EU-Type Examination CertificateBVS 17 ATEX E 029
MarkingEx-Hexagon II 2G Ex ia IIC T4/T3 Gb
Ex-Hexagon II 2D Ex tb [ia] IIIC T70°C Db
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2014
International approvals
CSA approval
Control drawing116-0435
IECEx approval
IECEx certificateIECEX BVS 17.0023
Accessories
Designationbattery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately)
mounting set W-ACC-F8MK
threads (NPT 1/2", NPT 3/4", G 1/2, M20)
Узнать цену
Каталожный номер: 219035
Electrical specifications
Nominal voltage3.6 V
Nominal current5 mA
Nominal capacity19 Ah , capacity can varies with usage conditions
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature15 ... 30 °C (59 ... 86 °F) recommended
-40 ... 80 °C (-40 ... 176 °F) at accelerated derating
Mechanical specifications
Massapprox. 90 g
DimensionsØ33 x 61,5 mm (1.3 x 2.4 inch)
Розничная цена
118 $ с НДС 11 225 с НДС
array(31) { ["id"]=> string(5) "95774" ["product_id"]=> string(6) "152393" ["id_1c"]=> NULL ["sku"]=> string(6) "219035" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(11225) ["primary_price"]=> string(9) "118.15435" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(11225) ["unconverted_price"]=> float(118.15) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 211734
Supply
Rated voltage3.6 V DC , battery operated
Power dissipation/power consumption< 0.09 W
Input
Connectionterminals 1, 2, 3, 4
RTDtype Pt100, Pt1000 (IEC 751: 1995 GOST: alpha = 0.391)
Connection2-wire: 2 sensors, 3- or 4-wire: 1 sensor
Lead resistancemax. 10 &Omega
Measuring circuit monitoringsensor breakage
Thermocouplestype E, J, K, T (IEC 584-1)
Cold junction compensationinternal , external
Measuring circuit monitoringsensor breakage
Measurement rangetype K: -270 ... 1370 °C
type T: -270 ... 400 °C
type E: -270 ... 1000 °C
type J: -210 ... 1200 °C
Resistor
Measurement range0 ... 500 &Omega , 0 ... 4000 &Omega
VoltagemV Input
Measurement range-100 ... 100 mV , 0 ... 300 mV
Input resistance&ge 1 M&Omega
Output
Output variablesPV: input 1 (°C, &Omega, mV)
SV: input 2 (°C, &Omega, mV)
TV: CJC temperature (°C)
estimated battery life (days)
battery voltage (volts)
residual battery capacity (%)
Transfer characteristics
Accuracy- internal cold junction compensation error ± 1,5 °C (typ. acc. to IEC 61298-3)
- external cold junction compensation error ± 1 °C (typ.)
- resolution error < 0.1 °C
- accuracy TC ± 20 µV
- accuracy RTD: ± 100 m&Omega
Indicators/settings
Parameter assignment- sampling period: 1, 2, 5, 10, 30 seconds or 1, 2, 5, 10, 30, 60 minutes
- transmit power: configurable 0 dBm or 10 dBm (EIRP)
- sensor type
- mapping of input measuring values 1 and 2 into primary variable (PV) and secondary variable (SV)
- publishing of up to three messages from the device, transmission rate selectable from 4 seconds to 60 minutes
Directive conformity
Electromagnetic compatibility
Directive 2004/108/ECEN 61326-1:2006
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 99/5/ECETSI EN 300328: V1.7.1 (2006-10), ETSI EN 301489-17: V1.2.1 (2002-08), EN 60950:2001
FCC CFR47 Part 15 B and CANSI C63.4-2003
Conformity
Degree of protectionIEC 60529
AccuracyIEC 61298-3
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-20 ... 70 °C (-4 ... 158 °F)
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
test setup and execution acc. to EN 60068-2-60
Mechanical specifications
Degree of protectionIP65
Massapprox. 1000 g
Dimensions77 x 129 x 177 mm (3 x 5.08 x 6.97 inch)
Mountingpanel or pole mounting
Data for application in connection with hazardous areas
EC-Type Examination CertificateIMQ 09 ATEX 008X
Group, category, type of protectionEx-Hexagon II 2(1)G Ex ia [ia] IIC T4
Directive conformity
Directive 94/9/ECEN 60079-0:2006, EN 60079-11:2007, EN 60079-26:2007
International approvals
FM approvalCoC 3042534
IECEx approvalIECEx INE 09.0025X
Approved forEx ia IIC T4
Accessories
Designationbattery W-BAT-B1-Li mandatory for use in connection with hazardous areas (order separately)
Mounting set W-ACC-F7MK
External cold junction compensation W-ACC-CJC
Розничная цена
1 404 $ с НДС 133 404 с НДС
array(31) { ["id"]=> string(5) "95773" ["product_id"]=> string(6) "152392" ["id_1c"]=> NULL ["sku"]=> string(6) "211734" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(133404) ["primary_price"]=> string(11) "1404.210504" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(133404) ["unconverted_price"]=> float(1404.2) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: T46565
Supply
Rated voltage20 ... 30 V DC SELV/PELV
Power consumption< 5 W
External bus
Connectionscrew terminals for
- 0.2 ... 4 mm2 (rigid wire)
- 0.2 ... 2.5 mm2 (flexible wire)
Interface 1Ethernet
10 BASE-T/100 BASE-TX , full galvanic isolation
ProtocolHART UDP, MODBUS TCP
Interface 2RS-485
ProtocolHART, MODBUS RTU
Transfer ratemax. 115 kBit/s
Galvanic isolation
Interface/interfacebasic insulation according to IEC 61140, rated insulation voltage 50 Veff
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 2014/53/EUEN 300328: V2.1.1
EN 301489-17: V1.3.2
FCC CFR47 Part 15 B and CANSI C63.4-2003
Conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
test setup and execution acc. to EN 60068-2-60
Mechanical specifications
Degree of protectionIP66/IP67
Massapprox. 1 kg
Dimensions258 mm x 114 mm x 84 mm
without antenna and cable glands
Mountingpanel mounting
Data for application in connection with hazardous areas
EU-Type Examination CertificateFM 12 ATEX 0061
MarkingEx-Hexagon II 3 G Ex nA IIC T4 Gc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-15:2010
International approvals
FM approvalCoc3042646
Approved forNI Class I, Div. 2, GPS A-D
NI Class II, Class III, Div. 2, GPS E-G
IECEx approvalIECEx FMG 12.0002
Approved forEx nA IIC T4 Gc , Ex nAc T4
Узнать цену
Добавлено в корзину!

Товаров: 0

На сумму: 0

Продолжить покупки
Оформить заказ

Купить оптом Беспроводные решения Pepperl+Fuchs

Клиенты

Блог

Подписка

Последнее на форуме

ООО "Зипстор"
127282, RU, Московская область, Москва, ул. Полярная, 33, стр. 3
+7 (800) 551-66-17
info@zipstore.ru