Атол 30Ф не включается (заводской брак)
Валерий
14 января 2022
| Описание оборудования | ||
|---|---|---|
| Raritan Dominion KVM Switch | ||
| Supply | ||
|---|---|---|
| Rated voltage | 7.2 V DC , battery operated | |
| Electrical specifications | ||
| Output rated operating current | 4 ... 20 mA | |
| Supply | loop power for field devices voltage 8 ... 23 V DC, adjustable in steps of 0.1 V | |
| Input | ||
| Suitable field devices | usable for: - one point-to-point connection with a HART field device, or - one point-to-point connection with a 4 ... 20 mA field device, or - up to four externally powered HART field devices operating in multidrop mode | |
| Connection | terminals 1, 2, 3, 4, 5, 6 multiple wirings available , depending on operating mode | |
| Current | 4 ... 20 mA | |
| HART communication | ||
| Protocol | HART 7.3, backward compatible | |
| Number of devices | - one passive 4 ... 20 mA/HART field device - up to 4 HART field devices in multidrop mode | |
| Transfer rate | 1200 Bit/s | |
| Parameters | primary/secondary master, preambles, retries and short address scan ranges | |
| Output | ||
| Output variables | PV: loop current SV, TV, QV:configurable according to user requirement - adapter: temperature, battery voltage, energy consumed and estimated battery life-time - 4 ... 20 mA device: scaled or linearized process value - HART device: up to four process variables | |
| Transfer characteristics | ||
| Accuracy | current input: 0.125 % of measuring range | |
| Influence of ambient temperature | current input: 5 µA/K | |
| Indicators/settings | ||
| Parameter assignment | - wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP) - device variables mapping - publishing of up to ten burst messages in a wireless network, period and trigger mode selectable - notification of up to five events from adapter and/or connected device(s) in a wireless network - scaling and linearization of 4 ... 20 mA signal of connected analog device - tuning of supply parameters for the connected device - locking/unlocking of device parameterization | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013, CLASS A | |
| Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. | |
| Directive 2014/53/EU | EN 300328 V2.1.1:2017 , EN 301489-17 V3.1.1:2017 , EN 301489-1 V2.1.1:2017 | |
| FCC CFR47 Part 15 B and C | ANSI C63.4-2003 | |
| RoHs | ||
| Directive 2011/65/EU (RoHS) | EN 50581:2012 | |
| Conformity | ||
| Degree of protection | IEC 60529 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Vibration resistance | 20 ... 2000 Hz, 0,01 g2/Hz | |
| Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 test setup and execution acc. to EN 60068-2-60 | |
| Mechanical specifications | ||
| Degree of protection | IP66 | |
| Material | Aluminum | |
| Mass | approx. 1000 g | |
| Dimensions | 92 x 89.5 x 92.8 mm (without cable glands and antenna) | |
| Mounting | mounting on field device , panel or pole mounting | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | BVS 17 ATEX E 029 | |
| Marking | II 2G Ex ia IIC T4/T3 Gb II 2D Ex tb [ia] IIIC T70°C Db | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2014 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | 116-0435 | |
| IECEx approval | ||
| IECEx certificate | IECEX BVS 17.0023 | |
| Accessories | ||
| Designation | battery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately) mounting set W-ACC-F8MK threads (NPT 1/2", NPT 3/4", G 1/2, M20) | |
| Electrical specifications | ||
|---|---|---|
| Nominal voltage | 3.6 V | |
| Nominal current | 5 mA | |
| Nominal capacity | 19 Ah , capacity can varies with usage conditions | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | 15 ... 30 °C (59 ... 86 °F) recommended -40 ... 80 °C (-40 ... 176 °F) at accelerated derating | |
| Mechanical specifications | ||
| Mass | approx. 90 g | |
| Dimensions | Ø33 x 61,5 mm (1.3 x 2.4 inch) | |
| Описание оборудования | ||
|---|---|---|
| End Cap for Power Bus | ||
| Mechanical specifications | ||
|---|---|---|
| Cable diameter | 5 ... 12 mm | |
| Material | brass , PA | |
| Mass | 160 g | |
| Process connection | G1A | |
| Ambient conditions | ||
|---|---|---|
| Ambient temperature | 0 ... 55 °C (32 ... 131 °F) | |
| Relative humidity | 5 ... 90 %, non-condensing | |
| Mechanical specifications | ||
| Connection | ||
| Device | 16 x IDC female connector, 14-pin | |
| Cable length | 0.45 m | |
| Ambient conditions | ||
|---|---|---|
| Ambient temperature | 0 ... 55 °C (32 ... 131 °F) | |
| Relative humidity | 5 ... 90 %, non-condensing | |
| Mechanical specifications | ||
| Connection | ||
| Device | 1 x IDC female connector, 26-pin | |
| Cable length | 1 m | |
| Mechanical specifications | ||
|---|---|---|
| Degree of protection | IP66 (15 inch / 19 inch) keyboard housing, optional: IP66 (on the back) , depending on mouse type at front - refer to datasheet EXTA2 | |
| Material | AG1: stainless steel 1.4301 (304) option available upon request : AS1: stainless steel 1.4571 (316Ti) / stainless steel 1.4404 (316L) | |
| Mass | 27 kg (15 inch) 25 kg (19 inch) 4 kg (keyboard housing, optional) | |
| Dimensions | 582 x 490 x 213 mm (without panel) 582 x 490 x 229 mm (15 inch panel) 582 x 490 x 224 mm (19 inch panel) | |
| General specifications | ||
|---|---|---|
| Number of pins | 6 | |
| Electrical specifications | ||
| Rated voltage | 160 V | |
| Rated current | 8 A | |
| Mechanical specifications | ||
| Core cross-section | 0.14 ... 1.5 mm2 | |
| Housing | blue | |
| Mass | approx. 5 g | |
| Dimensions | (W x H x D) 33.3 mm x 12.4 mm x 20.8 mm | |
| Construction type | spring terminal | |
| General specifications | ||
|---|---|---|
| Number of pins | 6 | |
| Electrical specifications | ||
| Rated voltage | 160 V | |
| Rated current | 8 A | |
| Mechanical specifications | ||
| Core cross-section | 0.14 ... 1.5 mm2 | |
| Housing | blue | |
| Mass | approx. 5 g | |
| Dimensions | (W x H x D) 33.3 mm x 12.4 mm x 20.8 mm | |
| Construction type | spring terminal | |
| Mechanical specifications | ||
|---|---|---|
| Construction type | protective conductor terminal block 0.2 ... 4 mm2 | |
| Electrical specifications | ||
|---|---|---|
| Rated voltage | 300 V AC/DC | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 80 °C (-4 ... 176 °F) | |
| Mechanical specifications | ||
| Connection | 37 pins/32 pins | |
| Material | ||
| Connector | plastic/plastic | |
| Cable | 22 AWG | |
| Construction type | 22 AWG 7/0096 tinned copper 18 individual twisted pairs overall foil | |
| Cable length | 10 m | |
| Shielding | aluminum/poly foil 100% coverage 24 AWG 7/32 T.C. DW. | |
| Data for application in connection with hazardous areas | ||
| Directive conformity | UL/cULus RoHS compliant | |
| Electrical specifications | ||
|---|---|---|
| Operating voltage | 660 V DC / 1000 V AC max. | |
| Operating current | 1600 A max. | |
| Mechanical specifications | ||
| Enclosure cover | detachable , optional hinges | |
| Cover fixing | Stainless steel hexagonal head screws | |
| Degree of protection | IP66 (IP67 with O-ring) | |
| Cable entry | see PDF data sheet | |
| Defined entry area | see PDF data sheet | |
| Material | ||
| Enclosure | Aluminum alloy | |
| Finish | painted grey | |
| Mass | see PDF data sheet | |
| Mounting | see PDF data sheet | |
| Ambient conditions | ||
| Ambient temperature | see PDF data sheet | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | ||
| Group, category, type of protection, temperature class | [Ex] II 2 GDEx d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
| International approvals | ||
| IECEx approval | IECEx INE 14.0029X | |
| Conformity | ||
| Degree of protection | EN60529 | |
| General information | ||
| Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Electrical specifications | ||
|---|---|---|
| Operating voltage | 1100 V AC max. | |
| Operating current | 350 A max. | |
| Mechanical specifications | ||
| Enclosure cover | fully detachable , concealed hinges | |
| Cover fixing | see PDF data sheet | |
| Degree of protection | IP66 | |
| Cable entry | see PDF data sheet | |
| Gland plate on face(s) | see PDF data sheet | |
| Defined entry area | see PDF data sheet | |
| Terminal assembly | ||
| Rail orientation | see PDF data sheet | |
| Number of rails | see PDF data sheet | |
| Usable length per rail | see PDF data sheet | |
| Terminal type | Standard see PDF data sheet, other terminal types optional | |
| Number of terminals per rail | see PDF data sheet | |
| Material | ||
| Enclosure | 1.5 mm 316L, (1.4404) stainless steel | |
| Gland plate | 3 mm 316L, (1.4404) stainless steel | |
| Finish | electropolished | |
| Seal | one piece closed cell neoprene , optional silicone | |
| Mass | see PDF data sheet | |
| Dimensions | see PDF data sheet | |
| Mounting | see PDF data sheet | |
| Grounding | M10 internal/external brass grounding bolt through enclosure body | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 40 °C (-40 ... 104 °F) , optional -50 ... 120 °C (-58 ... 248 °F) | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | SIRA 99 ATEX 3199 | |
| Marking | see PDF data sheet | |
| International approvals | ||
| IECEx approval | IECEx SIR 06.0074 | |
| INMETRO | TÜV 13.1665X | |
| EAC approval | TC RU C-DE.GB06.B.00567 | |
| Conformity | ||
| Degree of protection | EN60529 | |
| General information | ||
| Ordering information | This terminal box will be delivered completely configured and assembled ready for use. For configuration details please contact customer service. | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Accessories | ||
| Optional accessories | see PDF data sheet | |
| Electrical specifications | ||
|---|---|---|
| Operating voltage | 690 V max. | |
| Rated impulse withstand voltage | 6 kV | |
| Rated frequency | 50/60 Hz | |
| Short circuit current limitation | recommended: 35 A, gG | |
| Operating current | 25 A max. | |
| Terminal capacity | ||
| Main terminals capacity | 2x 1.5 ... 4 mm2 | |
| Main terminals torque | 2 Nm | |
| Grounding terminals capacity | 2x 1.5 ... 4 mm2 | |
| Grounding terminals torque | 2 Nm | |
| Rated insulation voltage | 800 V | |
| Function | switch disconnector | |
| Color | black | |
| Contact configuration | 3x NO | |
| Switching configuration | 2 position changeover with left OFF | |
| Switching diagram | D01 | |
| Usage category | AC23: 690 V AC - 16 A / 500 V AC - 20 A / 400 V AC - 25 A AC3: 690 V AC - 16 A / 500 V AC - 20 A / 400 V AC - 25 A | |
| Number of poles | 3 | |
| Operator action | engage - engage | |
| Lockable | in 'OFF' position threefold padlockable | |
| Labeling | 0 - I | |
| Mechanical specifications | ||
| Enclosure range | GL | |
| Enclosure cover | fully detachable | |
| Cover fixing | M6 stainless steel slot head screws | |
| Degree of protection | IP65 | |
| Cable entry face B | ||
| M25 quantity | 2 | |
| M25 series | Cable Glands, Plastic | |
| M25 type | CG.PEDS.M25.* | |
| M25 clamping range | 9 ... 17 mm | |
| Defined entry area | face B | |
| Material | ||
| Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
| Finish | inherent color black | |
| Seal | silicone cord | |
| Mass | 1.75 kg | |
| Dimensions | ||
| Height (A) | 160 mm | |
| Width (B) | 160 mm | |
| Depth (C) | 91 mm | |
| External dimension with operating element (C1) | 141 mm | |
| Mounting holes distance (G) | 110 mm | |
| Mounting holes distance (H) | 140 mm | |
| Mounting holes diameter (J) | 6.5 mm | |
| Tightening torque | ||
| Nut torque at enclosure (SW1) | see datasheets of cable glands | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) @ T4 | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
| Marking | II 2 GD Ex db eb IIC T* Gb Ex tb IIIC T** °C Db T4/T130 °C @ Ta +55 °C | |
| International approvals | ||
| IECEx approval | IECEx CML 16.0008X | |
| Conformity | ||
| Degree of protection | EN 60529 | |
| Usage category | IEC / EN 60947-3 | |
| General information | ||
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| General specifications | ||
|---|---|---|
| Construction type | sensor: silicium sensor metall diaphragm | |
| Supply | ||
| Rated voltage | versions for safe area: 11.5 ... 45 V DC, 2-wire 11.5 ... 35 V DC, HART, 2-wire 9 ... 32 V DC, PROFIBUS PA version for hazardous area see safety information (SI) | |
| Input | ||
| Measured variable | absolute or relative pressure | |
| Measurement range | 0.4 ... 400 bar max. turn down: 100:1 | |
| Output | ||
| Output signal | 4 ... 20 mA , analog , 2-wire 4 ... 20 mA with superimposed digital communication protocol HART 6.0, 2-wire digital communication signal PROFIBUS PA (Profile 3.02) | |
| Communication | 4 ... 20 mA HART (standard) PROFIBUS PA (option) | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006 , EN 61326-2-5:2006 | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Degree of protection | IEC 60529:2001 | |
| Measurement accuracy | ||
| Accuracy | reference accuracy: ±0.15 % (standard), ±0.075 % (platinum) The reference accuracy comprises the non-linearity according to limit point setting, hysteresis and non-reproducibility acc. to IEC 60770. The data refer to the calibrated span. | |
| Long-term drift | up to ±0.1 % of upper range limit (URL)/year | |
| Operating conditions | ||
| Process conditions | ||
| Medium temperature | -40 ... 125 °C (-40 ... 257 °F) hygienic versions: -40 ... 130 °C (-40 ... 266 °F), 150 °C/1h (302 °F/1h) | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) with display : -20 ... 70 °C (-4 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP66, NEMA 4X IP68, NEMA 6P (24 hours in water 1.83 m (6 ft) deep) IP69K (with separate housing and FEP cable) | |
| Connection | gland M20 thread M20, G1/2, NPT1/2 device plug M12 HAN7D Harting connector, angled valve connector acc. ISO 4400, cable 5 m | |
| Material | materials in contact with process : 316L, Alloy C, rhodium>gold housing: - die-cast aluminum with protective powder-coating on polyester base, housing F31 - stainless steel AISI 316L (1.4404), housing F15 measuring cell seal: no, welded measuring cell | |
| Process connection | threads ISO 228: G1/2, G1, G1-1/2, G2 threads ANSI: NPT1/2, NPT1, NPT1-1/2, NPT2 hygienic process connections: Clamp, Varivent, DRD, DIN 11851, DIN 11864, NEUMO, APV, uni adapter flanges: EN 1092-1: DN 25 ... DN 80, ANSI 16.5: 1 ... 4 inch, JIS B2220 | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | see instruction manuals (SI) | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2009 | |
| International approvals | ||
| FM approval | see instruction manuals (SI) | |
| CSA approval | see instruction manuals (SI) | |
| IECEx approval | see instruction manuals (SI) | |
| Certificates and approvals | ||
| Drinking water approval | NSF61 approval | |
| Overspill protection | see approval (ZE) | |
| Marine approval | German Lloyd (GL) | |
| Accessories | ||
| Designation | see technical information (TI) | |
| General specifications | ||
|---|---|---|
| Equipment architecture | A measuring system consists of a magnet-operated immersion probe LMC****-***-I-Ex with built-in converter and a transmitter power supply KFD2-STC4-Ex1 or of a magnet-operated immersion probe LMC****-***-O4-Ex and a potentiometer converter KFD2-PT2-Ex1. | |
| Output | ||
| Connection | version I: 2-wire, 4 ... 20 mA version O4: 3-wire, potentiometer connection approx. 40 k&Omega | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61000-6-2:2006 , EN 61000-6-4:2011 | |
| Conformity | ||
| Degree of protection | IEC 60529:2000 | |
| Measurement accuracy | ||
| Accuracy | resolution: - version LMC5: 5 mm - version LMC15: 15 mm | |
| Operating conditions | ||
| Process conditions | ||
| Process temperature | -20 ... 100 °C (-4 ... 212 °F) | |
| Process pressure (static pressure) | &le 16 bar (232.1 psi) | |
| Density | version S1: &ge 0.6 g/cm3 version S2: &ge 0.8 g/cm3 version S3: &ge 0.7 g/cm3 | |
| Ambient conditions | ||
| Ambient temperature | terminal box: -50 ... 60 °C (-58 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP65 | |
| Connection | Version I: 2 terminals, max. 2.5 mm2 Version O4: 3 terminals, max. 2.5 mm2 | |
| Material | float, guide tube, process connection: stainless steel 1.4571/316Ti terminal box: aluminum die-casting | |
| Dimensions | float: - version S1: ball &empty80 mm - version S2: cylinder &empty44 mm x 52 mm - version S3: ball &empty52 mm guide tube: - version LMC5: &empty14 mm, max. length 3000 mm - version LMC15: &empty12 mm, max. length 3000 mm terminal box: 80 x 75 x 57 mm | |
| Process connection | thread G1-1/2A, G2A to DIN/ISO 228/1 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | KEMA 03 ATEX 1497 X | |
| Group, category, type of protection, temperature class | II 1/2G EEx ia IIC T4...T6 | |
| Voltage | 28 V | |
| Current | 120 mA | |
| Internal capacitance | 0 nF | |
| Internal inductance | 0 µH | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007 | |
| Accessories | ||
| Optional accessories | LML-FS1 float, ball, Ø80 mm, 1.4571/316Ti LML-FS4 float, ball, Ø44 mm, 1.4571/316Ti LML-FS5 float, ball, Ø52 mm, Titanium LML-FS6 float, cylinder, Ø44 mm x 52 mm, 1.4571/316Ti | |
| General specifications | ||
|---|---|---|
| Function principle | ring magnet as switching element in the float, reed contact number of contacts: - version LML1: 1 contact - version LML2: 2 contacts - version LML3: 3 contacts switching function: - version DO: with rising level NC contact - version DS: with rising leve NO contact - version DW: with rising level change-over contact | |
| Equipment architecture | A measuring system consists of a magnet-operated immersion probe LML*S*-**S-**-Ex and a (up to 3) isolated amplifier(s) with certified intrinsically safe circuit, for example KFD2-SR2-Ex1.W. | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61000-6-2:2006 , EN 61000-6-4:2011 | |
| Conformity | ||
| Degree of protection | IEC 60529:2000 | |
| Operating conditions | ||
| Process conditions | ||
| Process temperature | -30 ... 150 °C (-22 ... 302 °F) | |
| Process pressure (static pressure) | &le 25 bar (362.6 psi) | |
| Density | version S2: &ge 0.8 g/cm3 version S3: &ge 0.7 g/cm3 | |
| Ambient conditions | ||
| Ambient temperature | terminal box: -50 ... 60 °C (-58 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP65 | |
| Connection | max. 6 terminals, max. 2.5 mm2 | |
| Material | float, guide tube, process connection: stainless steel 1.4571/316Ti terminal box: aluminum die-casting | |
| Dimensions | float: - version S2: cylinder &empty44 mm x 52 mm - version S3: ball &empty52 mm guide tube: &empty12 mm, max. length 3000 mm terminal box: 80 x 75 x 57 mm | |
| Process connection | thread G1-1/2A, G2A to DIN/ISO 228/1 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | KEMA 03 ATEX 1496 X | |
| Group, category, type of protection, temperature class | II 1/2G EEx ia IIC T3...T6 | |
| Voltage | 36 V | |
| Current | 100 mA | |
| Internal capacitance | 0 nF | |
| Internal inductance | 0 µH | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007 | |
| Accessories | ||
| Optional accessories | LML-Z11 set collar, 1.4571/316Ti LML-FS2 float, cylinder, Ø44 mm x 52 mm, 1.4571/316Ti LML-FS3 float, ball, Ø52 mm, 1.4571/316Ti | |
| General specifications | ||
|---|---|---|
| Signal type | Analog input | |
| Supply | ||
| Connection | Power Rail or terminals 14+, 15- | |
| Rated voltage | 20 ... 30 V DC | |
| Rated current | 75 mA | |
| Power dissipation | 1 W | |
| Power consumption | 2.25 W (typ. 1.68 W) | |
| Input | ||
| Connection side | field side | |
| Measurement range | terminals 1+, 3-: voltage 0/1 ... 5 V, load &ge 50 k&Omega or voltage 0/2 ... 10 V, load &ge 100 k&Omega terminals 2+, 3-: current 0/4 ... 20 mA load &le 50 &Omega | |
| Output | ||
| Connection side | control side | |
| Output I, II | terminals 7, 8, 9 10, 11, 12 | |
| Contact loading | 250 V AC / 4 A / cos &phi > 0.7 40 V DC / 2 A resistive load | |
| Output III | device configuration : terminals 4, 5, 6 | |
| Transfer characteristics | ||
| Deviation | &le 1 % | |
| Input delay | 100 ms | |
| Indicators/settings | ||
| Display elements | LEDs | |
| Control elements | DIP-switch potentiometer | |
| Configuration | via DIP switches via potentiometer | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Insulation coordination | EN 50178 | |
| Galvanic isolation | EN 50178 | |
| Degree of protection | IEC 60529 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 120 g | |
| Dimensions | 20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) , housing type B2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| General specifications | ||
|---|---|---|
| Measuring method | The tuning fork is brought to its resonance frequency by means of a piezoelectric drive. If the tuning fork is covered by liquid, this frequency changes. The electronics monitor the resonance frequency and indicate whether the tuning fork is freely vibrating or is covered by liquid. | |
| Construction type | compact device device with short tube | |
| Operating mode | MAX = maximum safety: The device keeps the electronic switch closed as long as the liquid level is below the fork. example application: overspill protection MIN = minimum safety: The device keeps the electronic switch closed as long as the fork is immersed in liquid. example application: dry running protection of pumps The electronic switch opens if the limit is reached, if a fault occurs or in the event of a power fails (quiescent current principle) | |
| Supply | ||
| Rated voltage | - DC-PNP: 10 ... 35 V DC, 3-wire - AC/DC: 20 ... 253 V AC/DC, 2-wire | |
| Current consumption | - DC-PNP: < 15 mA - AC/DC: < 3.8 mA | |
| Input | ||
| Measured variable | density | |
| Measurement range | min. 0.7 g/cm3, optional> 0.5 g/cm3 | |
| Output | ||
| Output type | switch output | |
| Switching current | max. 250 mA | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006 | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Electromagnetic compatibility | NE 21 | |
| Degree of protection | IEC 60529 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-64 | |
| Climate class | DIN EN 60068-2-38/IEC 68-2-38 | |
| Measurement accuracy | ||
| Reference operating conditions | - ambient temperature: 25 °C (+77 °F) - process pressure: 1 bar (14.5 psi) - fluid: water (density: approx. 1 g/cm3, viscosity: 1 mm2/s) - medium temperature: 25 °C (+77 °F) - density setting: > 0.7 g/cm3 - switching time delay: standard (0,5 s, 1 s) | |
| Measured value resolution | < 0.5 mm | |
| Measuring frequency | approx. 1100 Hz in air | |
| Switching point | 13 mm ± 1 mm | |
| Non-repeatability | ± 1 mm acc. to DIN 61298-2 | |
| Hysteresis | max. 3 mm | |
| Influence of ambient temperature | negligible | |
| Influence of medium temperature | -25 µm/°C | |
| Influence of medium pressure | -20 µm/bar | |
| Switching time | - 0.5 s when tuning fork is covered - 1.0 s when tuning fork is uncovered - other switching times on request | |
| Operating conditions | ||
| Installation conditions | ||
| Installation position | see section mounting position | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Shock resistance | a = 300 m/s2 = 30 g, 3 planes x 2 directions x 3 shocks x 18 ms, as per test Ea | |
| Vibration resistance | a(RMS) = 50 m/s2, ASD = 1.25 (m/s2)2/Hz, f = 5 to 2000 Hz, t = 3 x 2 h | |
| Process conditions | ||
| Medium temperature | -40 ... +100 °C (-40 ... +212 °F) -40 ... +150 °C (-40 ... +302 °F) | |
| Process pressure (static pressure) | -1 ... +40 bar (-14.5 ... +580 psi) | |
| State of aggregation | liquid | |
| Density | min. 0.7 g/cm3, optional> 0.5 g/cm3 | |
| Viscosity | 1 ... 10000 mPa/s, dynamic viscosity | |
| Solid contents | < &empty5 mm | |
| Mechanical specifications | ||
| Degree of protection | - IP65/67, NEMA 4X enclosure (plug M12) - IP65, NEMA 4X enclosure (valve plug) - IP65/68, NEMA 4X/6P enclosure (cable) | |
| Connection | - cable 5 m - valve plug NPT1/2 - valve plug QUICKON - valve plug M16 - plug M12 | |
| Material | see technical information (TI) | |
| Surface quality | Ra < 3.2 µm | |
| Mass | see technical information (TI) | |
| Dimensions | see technical information (TI) | |
| Process connection | - thread ISO 228 G1/2, G3/4, G1 - thread EN 10226 R1/2, R3/4, R1 - thread ASME MNPT1/2, MNPT3/4, MNPT1 | |
| Certificates and approvals | ||
| Overspill protection | Z-65.11-554 (overspill protection acc. to WHG) Z-65.40-555 (leak detection system acc. to WHG) If you need the approvals also in paper form, select the option WH in the type code. | |
| Accessories | ||
| Designation | see technical information (TI) | |
| General specifications | ||
|---|---|---|
| Measuring method | A metal plate at the end of the probe, within the insulation, and the surroundings (e. g. the silo walls) combine to form the two electrodes of a capacitor. If the probe is covered or free of material, then the capacitance changes and the LCL switches. | |
| Equipment architecture | The measuring system consists of: - the device - a supply point - the connected control systems, switching units, signalling systems (e. g. lamps, horns, PCS, PLC, etc.) | |
| Construction type | device with rod probe | |
| Operating mode | MAX = maximum safety: The device switches if the probe is covered or if the supply voltage is disconnected in a safety-oriented manner (signal on alarm). example application: overspill protection MIN = minimum safety: The device switches if the probe is uncovered or if the supply voltage is disconnected in a safetyoriented manner (signal on alarm). example application: dry-running protection | |
| Supply | ||
| Rated voltage | electrical connection E5: 10.8 ... 45 V DC, short-term pulse on 55 V DC electrical connection WA: 20 ... 235 V AC, 50/60 Hz or 20 ... 55 V DC | |
| Current consumption | electrical connection E5: max. 30 mA, reverse-polarity-proof electrical connection WA: max. 130 mA | |
| Electrical specifications | ||
| Surge protection | overvoltage category III | |
| Input | ||
| Measured variable | limit level (limit value) | |
| Measurement range | dielectric constant &ge 1.6 | |
| Output | ||
| Output signal | connection E5: switching PNP, Imax = 200 mA - overload and short circuit protection - residual voltage at transistor at Imax < 2.9 V connection WA: contact change-over, potential-free - Umax = 253 V - Imax = 4 A (AC) - Pmax = 1000 VA, cos &phi = 1, Pmax = 500 VA, cos &phi > 0.7 | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006 | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Electromagnetic compatibility | NE 21 | |
| Degree of protection | IEC 60529:2001 | |
| Vibration resistance | EN 60068-2-64 | |
| Climate class | EN 60068, part 2-38 (test Z/AD) | |
| Measurement accuracy | ||
| Reference operating conditions | vessel type: plastic vessel, ambient temperature: 73 °F (23 °C, 296 K), medium temperature: 73 °F (23 °C, 296 K) medium pressure pe: 0 bar, medium: dielectric constant = 2.6, conductivity: < 1 µS sensitivity setting: C | |
| Hysteresis | horizontal 4 mm (0.16 inch), vertical 7 mm (0.28 inch) | |
| Long-term drift | horizontal 3 mm (0.12 inch), vertical 6 mm (0.24 inch) | |
| Influence of medium temperature | depending on the filling material | |
| Switching time | approx. 0.5 s when covering and uncovering the sensor | |
| Operating conditions | ||
| Installation conditions | ||
| Installation position | any position | |
| Mounting location | The capacitive limit switch can be installed in silos made of different materials (e. g. metal, plastic, concrete). | |
| Process conditions | ||
| Process temperature | -40 ... 130 °C (-40 ... 266 °F) -40 ... 80 °C (-40 ... 176 °F) (Dust-Ex version) | |
| Medium pressure limits | -1 ... 25 bar | |
| State of aggregation | fluids and solids | |
| Solid contents | &le &empty 30 mm | |
| Bulk density | &le 200 g/l | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 80 °C (-40 ... 176 °F) -40 ... 60 °C (-40 ... 140 °F) (Dust-Ex version) | |
| Storage temperature | -40 ... 80 °C (-40 ... 176 °F) | |
| Shock resistance | device with F34 housing: 7 J | |
| Vibration resistance | a(RMS) = 50 m/s2, ASD = 1.25 (m/s2)2/Hz, f = 5 to 2000 Hz, t = 3 x 2 h | |
| Mechanical specifications | ||
| Degree of protection | IP66, NEMA 4 | |
| Connection | gland M20 thread G1/2, NPT1/2 | |
| Material | F14 housing: polyester PBT-FR F34 housing F34: aluminum Probe: PPS GF40 | |
| Dimensions | max. &empty94 mm (3.7 inch), length 391 mm (15.4 inch) | |
| Process connection | thread R1 acc. to EN 10226, BSPT, adapter for R1-1/2 and G1-1/2 see accessories thread NPT1 to ANSI B 1.20.1, adapter for NPT1-1/4 see accessories | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | see instruction manuals (SI) | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2009 | |
| Accessories | ||
| Optional accessories | LCL-Z10 cover with sight glass for F14 housing LCL-Z11 adapter for R1-1/2, EN 10226 LCL-Z12 adapter for G1-1/2, DIN ISO 228 LCL-Z13 adapter for NPT1-1/4, steel LCL-Z15 adapter for NPT1-1/4, 1.4571 | |
| General specifications | ||
|---|---|---|
| Equipment architecture | switching element: changeover switching on point: 15 mbar ± 3 mbar, switching off point: 9 mbar ± 3 mbar max. hydrostatic pressure: 500 mbar | |
| Supply | ||
| Rated voltage | 253 V AC , 50/60 Hz | |
| Current consumption | max. 1 A | |
| Conformity | ||
| Degree of protection | IEC 60529:2001 | |
| Operating conditions | ||
| Process conditions | ||
| Process temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP54 | |
| Connection | flat plug 6.3 x 0.8 mm (0.25 x 0.03 inch), DIN 46244 | |
| Material | housing: PA pipe: stainless steel 1.4571/316Ti or PVC | |
| Dimensions | housing: 100 x 75 x 80 mm (4 x 3 x 3.1 inch) pipe: length L 180 ... 5000 mm (0.6 ... 16.5 ft) | |
| Process connection | thread G1/2 to ISO 228 | |
| General specifications | ||
|---|---|---|
| Measuring method | The device is a measuring system that functions according to the time-of-flight method. The distance from the reference point (process connection of the measuring device) to the product surface is measured. | |
| Construction type | device with rod probe device with rope probe | |
| Supply | ||
| Rated voltage | 11.5 ... 35 V DC, 2-wire 10.4 ... 48 V DC, 4-wire 90 ... 253 V AC, 50/60 Hz | |
| Input | ||
| Measured variable | distance between reference point and product surface | |
| Measurement range | rod probe: 4 m (13 ft) rope probe: 12 m (39 ft) | |
| Output | ||
| Output signal | 4 ... 20 mA 2 x 4 ... 20 mA | |
| Communication | 4 ... 20 mA HART (standard) PROFIBUS PA (option) | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006 | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Degree of protection | IEC 60529:2001 | |
| Measurement accuracy | ||
| Accuracy | digital: ±2 mm (0.08 inch) analog: 0.02 % sum of non-linearity, non-repeatability and hysteresis included in the maximum measured error | |
| Operating conditions | ||
| Process conditions | ||
| Process temperature | -20 ... 80 °C (-4 ... 176 °F) | |
| Process pressure (static pressure) | -1 ... 6 bar (-14.5 ... 87 psi) | |
| Dielectric constant | rod probe: DC &ge 1.6 rope probe: DC &ge 1.6 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 80 °C (-40 ... 176 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP68, NEMA 6P (24 hours in water 1.83 m (6 ft) deep) IP66, NEMA 4X | |
| Connection | gland M20 thread M20, G1/2, NPT1/2 device plug M12, 7/8 in | |
| Material | materials in contact with process : rod probe: 1.4404/316L rope probe: 1.4401/316 process connections: 1.4404/316L, PPS-GF40 process membran, seal: Viton | |
| Process connection | threads: G3/4, MNPT3/4 flanges: universal flange | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | see instruction manuals (SI) | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-1:2007 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 , EN 60079-31:2009 | |
| International approvals | ||
| IECEx approval | see instruction manuals (SI) | |
| Certificates and approvals | ||
| Overspill protection | see approval (ZE) | |
| Telecommunications | radio license FCC | |
| Accessories | ||
| Designation | see technical information (TI) | |
| Описание оборудования | ||
|---|---|---|
| Fieldbus Diagnostic Handheld | ||
| Описание оборудования | ||
|---|---|---|
| 24 V DC | ||
| Описание оборудования | ||
|---|---|---|
| 24 V DC | ||
| General specifications | ||
|---|---|---|
| Signal type | Digital Input | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 2 | |
| Supply | ||
| Connection | terminals 14, 15 | |
| Rated voltage | 207 ... 253 V AC, 45 ... 65 Hz | |
| Power dissipation | 1.2 W | |
| Power consumption | max. 1.3 W | |
| Input | ||
| Connection side | field side | |
| Connection | terminals 1+, 2+, 3- 4+, 5+, 6- | |
| Rated values | acc. to EN 60947-5-6 (NAMUR) | |
| Open circuit voltage/short-circuit current | approx. 8 V DC / approx. 8 mA | |
| Switching point/switching hysteresis | 1.2 ... 2.1 mA / approx. 0.2 mA | |
| Line fault detection | breakage I &le 0.1 mA , short-circuit I > 6 mA | |
| Pulse/Pause ratio | min. 20 ms / min. 20 ms | |
| Output | ||
| Connection side | control side | |
| Connection | output I: terminals 7, 8, 9 output II: terminals 10, 11, 12 | |
| Output I, II | signal relay | |
| Contact loading | 253 V AC/2 A/cos &phi > 0.7 126.5 V AC/4 A/cos &phi > 0.7 40 V DC/2 A resistive load | |
| Energized/De-energized delay | approx. 20 ms / approx. 20 ms | |
| Mechanical life | 107 switching cycles | |
| Transfer characteristics | ||
| Switching frequency | &le 10 Hz | |
| Indicators/settings | ||
| Display elements | LEDs | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2006 | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 150 g | |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | PTB 00 ATEX 2081 | |
| Marking | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
| International approvals | ||
| FM approval | ||
| Control drawing | 116-0035 | |
| UL approval | ||
| Control drawing | 116-0145 | |
| CSA approval | ||
| Control drawing | 116-0047 | |
| IECEx approval | IECEx PTB 11.0031 | |
| Approved for | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I | |
| General specifications | ||
|---|---|---|
| Signal type | Digital Input | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 2 | |
| Supply | ||
| Connection | Power Rail or terminals 14+, 15- | |
| Rated voltage | 20 ... 30 V DC | |
| Ripple | &le 10 % | |
| Rated current | &le 50 mA | |
| Power dissipation | 1 W | |
| Power consumption | < 1.3 W | |
| Input | ||
| Connection side | field side | |
| Connection | terminals 1+, 2+, 3- 4+, 5+, 6- | |
| Rated values | acc. to EN 60947-5-6 (NAMUR) | |
| Open circuit voltage/short-circuit current | approx. 8 V DC / approx. 8 mA | |
| Switching point/switching hysteresis | 1.2 ... 2.1 mA / approx. 0.2 mA | |
| Line fault detection | breakage I &le 0.1 mA , short-circuit I > 6 mA | |
| Pulse/Pause ratio | min. 20 ms / min. 20 ms | |
| Output | ||
| Connection side | control side | |
| Connection | output I: terminals 7, 8, 9 output II: terminals 10, 11, 12 | |
| Output I, II | signal, relay | |
| Contact loading | 253 V AC/2 A/cos &phi > 0.7 126.5 V AC/4 A/cos &phi > 0.7 40 V DC/2 A resistive load | |
| Minimum switch current | 2 mA / 24 V DC | |
| Energized/De-energized delay | approx. 20 ms / approx. 20 ms | |
| Mechanical life | 107 switching cycles | |
| Transfer characteristics | ||
| Switching frequency | &le 10 Hz | |
| Indicators/settings | ||
| Display elements | LEDs | |
| Control elements | DIP-switch | |
| Configuration | via DIP switches | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2006 | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 150 g | |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | PTB 00 ATEX 2080 | |
| Marking | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
| Fault indication output | ||
| Maximum safe voltage | 40 V DC (Attention! Um is no rated voltage.) | |
| Certificate | PF 08 CERT 0803 | |
| Marking | II (3)G [Ex ic Gc] IIC | |
| Certificate | TÜV 99 ATEX 1493 X | |
| Marking | II 3G Ex nA nC IIC T4 | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 | |
| International approvals | ||
| FM approval | ||
| Control drawing | 116-0035 | |
| CSA approval | ||
| Control drawing | 116-0047 | |
| IECEx approval | IECEx PTB 11.0034 | |
| Approved for | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I | |
| General specifications | ||
|---|---|---|
| Signal type | Digital Input | |
| Supply | ||
| Connection | Power Rail or terminals 14+, 15- | |
| Rated voltage | 19 ... 30 V DC | |
| Ripple | &le 10 % | |
| Rated current | 45 ... 70 mA | |
| Power dissipation | 1.2 W | |
| Input | ||
| Connection side | field side | |
| Connection | terminals 1-, 2+, 3- 4-, 5+, 6- | |
| Rated values | acc. to EN 60947-5-6 (NAMUR), see system description for electrical data | |
| Open circuit voltage/short-circuit current | approx. 8 V DC / approx. 8 mA | |
| Switching point/switching hysteresis | 1.2 ... 2.1 mA / approx. 0.2 mA | |
| Pulse/Pause ratio | min. 35 ms / min. 35 ms (non-AC operation) min. 70 ms / min. 70 ms (AC operation) | |
| Line fault detection | breakage I &le 0.15 mA , short-circuit I > 6 mA | |
| Output | ||
| Connection side | control side | |
| Connection | output I: terminals 7, 8 output II: terminals 8, 9 output III: terminals 10, 11 output IV: terminals 11, 12 | |
| Output I ... IV | Signal I ... Signal IV relay | |
| Contact loading | 253 V AC/2 A /cos &phi > 0.7 40 V DC/2 A resistive load | |
| Energized/De-energized delay | approx. 30 ms / approx. 30 ms | |
| Mechanical life | 5 x 106 switching cycles | |
| Collective error message | Power Rail | |
| Transfer characteristics | ||
| Switching frequency | &le 10 Hz (non-AC operation) &le 3 Hz (AC operation) | |
| Indicators/settings | ||
| Display elements | LEDs | |
| Control elements | DIP-switch | |
| Configuration | via DIP switches | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2006 | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 150 g | |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | ZELM 99 ATEX 0009 | |
| Marking | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
| Fault indication output | ||
| Maximum safe voltage | 40 V DC | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-26:2007 , EN 50303:2000 | |
| International approvals | ||
| UL approval | ||
| Control drawing | 116-0145 | |
| IECEx approval | IECEx TUN 04.0003 | |
| Approved for | [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I | |
| Описание оборудования | ||
|---|---|---|
| 230 V AC | ||
Товаров: 0
На сумму: 0