| General specifications | ||
|---|---|---|
| Construction type | sensor: silicium sensor metall diaphragm | |
| Supply | ||
| Rated voltage | versions for safe area: 11.5 ... 45 V DC, 2-wire 11.5 ... 35 V DC, HART, 2-wire 9 ... 32 V DC, PROFIBUS PA version for hazardous area see safety information (SI) | |
| Input | ||
| Measured variable | absolute or relative pressure | |
| Measurement range | 0.4 ... 400 bar max. turn down: 100:1 | |
| Output | ||
| Output signal | 4 ... 20 mA , analog , 2-wire 4 ... 20 mA with superimposed digital communication protocol HART 6.0, 2-wire digital communication signal PROFIBUS PA (Profile 3.02) | |
| Communication | 4 ... 20 mA HART (standard) PROFIBUS PA (option) | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006 , EN 61326-2-5:2006 | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Degree of protection | IEC 60529:2001 | |
| Measurement accuracy | ||
| Accuracy | reference accuracy: ±0.15 % (standard), ±0.075 % (platinum) The reference accuracy comprises the non-linearity according to limit point setting, hysteresis and non-reproducibility acc. to IEC 60770. The data refer to the calibrated span. | |
| Long-term drift | up to ±0.1 % of upper range limit (URL)/year | |
| Operating conditions | ||
| Process conditions | ||
| Medium temperature | -40 ... 125 °C (-40 ... 257 °F) hygienic versions: -40 ... 130 °C (-40 ... 266 °F), 150 °C/1h (302 °F/1h) | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) with display : -20 ... 70 °C (-4 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP66, NEMA 4X IP68, NEMA 6P (24 hours in water 1.83 m (6 ft) deep) IP69K (with separate housing and FEP cable) | |
| Connection | gland M20 thread M20, G1/2, NPT1/2 device plug M12 HAN7D Harting connector, angled valve connector acc. ISO 4400, cable 5 m | |
| Material | materials in contact with process : 316L, Alloy C, rhodium>gold housing: - die-cast aluminum with protective powder-coating on polyester base, housing F31 - stainless steel AISI 316L (1.4404), housing F15 measuring cell seal: no, welded measuring cell | |
| Process connection | threads ISO 228: G1/2, G1, G1-1/2, G2 threads ANSI: NPT1/2, NPT1, NPT1-1/2, NPT2 hygienic process connections: Clamp, Varivent, DRD, DIN 11851, DIN 11864, NEUMO, APV, uni adapter flanges: EN 1092-1: DN 25 ... DN 80, ANSI 16.5: 1 ... 4 inch, JIS B2220 | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | see instruction manuals (SI) | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2009 | |
| International approvals | ||
| FM approval | see instruction manuals (SI) | |
| CSA approval | see instruction manuals (SI) | |
| IECEx approval | see instruction manuals (SI) | |
| Certificates and approvals | ||
| Drinking water approval | NSF61 approval | |
| Overspill protection | see approval (ZE) | |
| Marine approval | German Lloyd (GL) | |
| Accessories | ||
| Designation | see technical information (TI) | |
| General specifications | ||
|---|---|---|
| Equipment architecture | A measuring system consists of a magnet-operated immersion probe LMC****-***-I-Ex with built-in converter and a transmitter power supply KFD2-STC4-Ex1 or of a magnet-operated immersion probe LMC****-***-O4-Ex and a potentiometer converter KFD2-PT2-Ex1. | |
| Output | ||
| Connection | version I: 2-wire, 4 ... 20 mA version O4: 3-wire, potentiometer connection approx. 40 k&Omega | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61000-6-2:2006 , EN 61000-6-4:2011 | |
| Conformity | ||
| Degree of protection | IEC 60529:2000 | |
| Measurement accuracy | ||
| Accuracy | resolution: - version LMC5: 5 mm - version LMC15: 15 mm | |
| Operating conditions | ||
| Process conditions | ||
| Process temperature | -20 ... 100 °C (-4 ... 212 °F) | |
| Process pressure (static pressure) | &le 16 bar (232.1 psi) | |
| Density | version S1: &ge 0.6 g/cm3 version S2: &ge 0.8 g/cm3 version S3: &ge 0.7 g/cm3 | |
| Ambient conditions | ||
| Ambient temperature | terminal box: -50 ... 60 °C (-58 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP65 | |
| Connection | Version I: 2 terminals, max. 2.5 mm2 Version O4: 3 terminals, max. 2.5 mm2 | |
| Material | float, guide tube, process connection: stainless steel 1.4571/316Ti terminal box: aluminum die-casting | |
| Dimensions | float: - version S1: ball &empty80 mm - version S2: cylinder &empty44 mm x 52 mm - version S3: ball &empty52 mm guide tube: - version LMC5: &empty14 mm, max. length 3000 mm - version LMC15: &empty12 mm, max. length 3000 mm terminal box: 80 x 75 x 57 mm | |
| Process connection | thread G1-1/2A, G2A to DIN/ISO 228/1 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | KEMA 03 ATEX 1497 X | |
| Group, category, type of protection, temperature class | II 1/2G EEx ia IIC T4...T6 | |
| Voltage | 28 V | |
| Current | 120 mA | |
| Internal capacitance | 0 nF | |
| Internal inductance | 0 µH | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007 | |
| Accessories | ||
| Optional accessories | LML-FS1 float, ball, Ø80 mm, 1.4571/316Ti LML-FS4 float, ball, Ø44 mm, 1.4571/316Ti LML-FS5 float, ball, Ø52 mm, Titanium LML-FS6 float, cylinder, Ø44 mm x 52 mm, 1.4571/316Ti | |
| General specifications | ||
|---|---|---|
| Measuring method | The device is a measuring system that functions according to the time-of-flight method. The distance from the reference point (process connection of the measuring device) to the product surface is measured. | |
| Construction type | device with rod probe device with rope probe | |
| Supply | ||
| Rated voltage | 11.5 ... 35 V DC, 2-wire 10.4 ... 48 V DC, 4-wire 90 ... 253 V AC, 50/60 Hz | |
| Input | ||
| Measured variable | distance between reference point and product surface | |
| Measurement range | rod probe: 4 m (13 ft) rope probe: 12 m (39 ft) | |
| Output | ||
| Output signal | 4 ... 20 mA 2 x 4 ... 20 mA | |
| Communication | 4 ... 20 mA HART (standard) PROFIBUS PA (option) | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006 | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Degree of protection | IEC 60529:2001 | |
| Measurement accuracy | ||
| Accuracy | digital: ±2 mm (0.08 inch) analog: 0.02 % sum of non-linearity, non-repeatability and hysteresis included in the maximum measured error | |
| Operating conditions | ||
| Process conditions | ||
| Process temperature | -20 ... 80 °C (-4 ... 176 °F) | |
| Process pressure (static pressure) | -1 ... 6 bar (-14.5 ... 87 psi) | |
| Dielectric constant | rod probe: DC &ge 1.6 rope probe: DC &ge 1.6 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 80 °C (-40 ... 176 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP68, NEMA 6P (24 hours in water 1.83 m (6 ft) deep) IP66, NEMA 4X | |
| Connection | gland M20 thread M20, G1/2, NPT1/2 device plug M12, 7/8 in | |
| Material | materials in contact with process : rod probe: 1.4404/316L rope probe: 1.4401/316 process connections: 1.4404/316L, PPS-GF40 process membran, seal: Viton | |
| Process connection | threads: G3/4, MNPT3/4 flanges: universal flange | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | see instruction manuals (SI) | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-1:2007 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 , EN 60079-31:2009 | |
| International approvals | ||
| IECEx approval | see instruction manuals (SI) | |
| Certificates and approvals | ||
| Overspill protection | see approval (ZE) | |
| Telecommunications | radio license FCC | |
| Accessories | ||
| Designation | see technical information (TI) | |
| General specifications | ||
|---|---|---|
| Sensing range | 0.3 ... 4 m , with fluids | |
| Transducer frequency | approx. 85 kHz | |
| Indicators/operating means | ||
| LED green | Power on | |
| LED red | 2 Hz flashing: error | |
| Electrical specifications | ||
| Operating voltage | 20 ... 30 V DC , ripple 10 %SS | |
| Power consumption | &le 1200 mW | |
| Output | ||
| Output type | 1 analog output 4 ... 20 mA, RL &le 500 Ohm, error &ge 21 mA 1 voltage output 0 ... 10 V, RL &ge 1000 Ohm, error &ge 10.5 V | |
| Resolution | 2 mm | |
| Deviation of the characteristic curve | 0.5 % of upper limit of measuring range | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP65 | |
| Connection | 5-pin V15 (M12 x 1) connector | |
| Material | ||
| Housing | PBT, polypropylene | |
| Transducer | PTFE (diaphragm surface) | |
| Mass | 220 g | |
| Mounting | G1½A connection | |