Атол 30Ф не включается (заводской брак)
Валерий
14 января 2022
| Описание оборудования | ||
|---|---|---|
| Single head system | ||
| Описание оборудования | ||
|---|---|---|
| Single head system | ||
| Описание оборудования | ||
|---|---|---|
| High-resolution light grid for detecting people and objects, set comprising emitter and receiver, field height: 1800 mm, light/dark on, 1 NPN output and 1 PNP output, M8 plug | ||
| Описание оборудования | ||
|---|---|---|
| Compact fire protection photoelectric sensor | ||
| Описание оборудования | ||
|---|---|---|
| Premium industrial door opener with the ability to differentiate between people and vehicles, can be operated remotely, detection range 9 m x 6.5 m, max. installation height 7 m, black housing, 2 relay contact outputs, cable connection | ||
| Описание оборудования | ||
|---|---|---|
| Premium industrial door opener with the ability to differentiate between people and vehicles, can be operated remotely, detection range 9 m x 6.5 m, max. installation height 7 m, black housing, 2 relay contact outputs, cable connection | ||
| Описание оборудования | ||
|---|---|---|
| Miniature photoelectric sensor with plug-in style housing for mounting in 13 mm hole | ||
| Описание оборудования | ||
|---|---|---|
| Laser light sensor for field monitoring | ||
| Описание оборудования | ||
|---|---|---|
| PGV colored tape, black | ||
| Описание оборудования | ||
|---|---|---|
| Print mark contrast sensor with IO-Link interface, 11 mm detection range, RGB light parallel with the longitudinal direction of the housing, light/dark on, 2 push-pull outputs, M12 plug | ||
| General specifications | ||
|---|---|---|
| Equipment architecture | A measuring system consists of a magnet-operated immersion probe LMC****-***-I-Ex with built-in converter and a transmitter power supply KFD2-STC4-Ex1 or of a magnet-operated immersion probe LMC****-***-O4-Ex and a potentiometer converter KFD2-PT2-Ex1. | |
| Output | ||
| Connection | version I: 2-wire, 4 ... 20 mA version O4: 3-wire, potentiometer connection approx. 40 k&Omega | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61000-6-2:2006 , EN 61000-6-4:2011 | |
| Conformity | ||
| Degree of protection | IEC 60529:2000 | |
| Measurement accuracy | ||
| Accuracy | resolution: - version LMC5: 5 mm - version LMC15: 15 mm | |
| Operating conditions | ||
| Process conditions | ||
| Process temperature | -20 ... 100 °C (-4 ... 212 °F) | |
| Process pressure (static pressure) | &le 16 bar (232.1 psi) | |
| Density | version S1: &ge 0.6 g/cm3 version S2: &ge 0.8 g/cm3 version S3: &ge 0.7 g/cm3 | |
| Ambient conditions | ||
| Ambient temperature | terminal box: -50 ... 60 °C (-58 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP65 | |
| Connection | Version I: 2 terminals, max. 2.5 mm2 Version O4: 3 terminals, max. 2.5 mm2 | |
| Material | float, guide tube, process connection: stainless steel 1.4571/316Ti terminal box: aluminum die-casting | |
| Dimensions | float: - version S1: ball &empty80 mm - version S2: cylinder &empty44 mm x 52 mm - version S3: ball &empty52 mm guide tube: - version LMC5: &empty14 mm, max. length 3000 mm - version LMC15: &empty12 mm, max. length 3000 mm terminal box: 80 x 75 x 57 mm | |
| Process connection | thread G1-1/2A, G2A to DIN/ISO 228/1 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | KEMA 03 ATEX 1497 X | |
| Group, category, type of protection, temperature class | II 1/2G EEx ia IIC T4...T6 | |
| Voltage | 28 V | |
| Current | 120 mA | |
| Internal capacitance | 0 nF | |
| Internal inductance | 0 µH | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007 | |
| Accessories | ||
| Optional accessories | LML-FS1 float, ball, Ø80 mm, 1.4571/316Ti LML-FS4 float, ball, Ø44 mm, 1.4571/316Ti LML-FS5 float, ball, Ø52 mm, Titanium LML-FS6 float, cylinder, Ø44 mm x 52 mm, 1.4571/316Ti | |
| General specifications | ||
|---|---|---|
| Function principle | ring magnet as switching element in the float, reed contact number of contacts: - version LML1: 1 contact - version LML2: 2 contacts - version LML3: 3 contacts switching function: - version DO: with rising level NC contact - version DS: with rising leve NO contact - version DW: with rising level change-over contact | |
| Equipment architecture | A measuring system consists of a magnet-operated immersion probe LML*S*-**S-**-Ex and a (up to 3) isolated amplifier(s) with certified intrinsically safe circuit, for example KFD2-SR2-Ex1.W. | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61000-6-2:2006 , EN 61000-6-4:2011 | |
| Conformity | ||
| Degree of protection | IEC 60529:2000 | |
| Operating conditions | ||
| Process conditions | ||
| Process temperature | -30 ... 150 °C (-22 ... 302 °F) | |
| Process pressure (static pressure) | &le 25 bar (362.6 psi) | |
| Density | version S2: &ge 0.8 g/cm3 version S3: &ge 0.7 g/cm3 | |
| Ambient conditions | ||
| Ambient temperature | terminal box: -50 ... 60 °C (-58 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP65 | |
| Connection | max. 6 terminals, max. 2.5 mm2 | |
| Material | float, guide tube, process connection: stainless steel 1.4571/316Ti terminal box: aluminum die-casting | |
| Dimensions | float: - version S2: cylinder &empty44 mm x 52 mm - version S3: ball &empty52 mm guide tube: &empty12 mm, max. length 3000 mm terminal box: 80 x 75 x 57 mm | |
| Process connection | thread G1-1/2A, G2A to DIN/ISO 228/1 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | KEMA 03 ATEX 1496 X | |
| Group, category, type of protection, temperature class | II 1/2G EEx ia IIC T3...T6 | |
| Voltage | 36 V | |
| Current | 100 mA | |
| Internal capacitance | 0 nF | |
| Internal inductance | 0 µH | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007 | |
| Accessories | ||
| Optional accessories | LML-Z11 set collar, 1.4571/316Ti LML-FS2 float, cylinder, Ø44 mm x 52 mm, 1.4571/316Ti LML-FS3 float, ball, Ø52 mm, 1.4571/316Ti | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 60 mm | |
| Installation | flush in non-magnetic metal | |
| Output polarity | DC | |
| Assured operating distance | 10 ... 48.6 mm | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 5000 Hz | |
| Hysteresis | 1 ... 10 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 2.5 V | |
| Operating current | 0 ... 200 mA | |
| No-load supply current | &le 10 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 2935 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| Protection class | II | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 75 °C (-13 ... 167 °F) | |
| Mechanical specifications | ||
| Connection type | cable PUR , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | stainless steel 1.4404 / AISI 316L | |
| Sensing face | PBT | |
| Housing diameter | 12 mm | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 1-axis | |
| Measurement range | 0 ... 360 ° | |
| Absolute accuracy | &le ± 0.5 ° | |
| Response delay | &le 20 ms | |
| Resolution | &le 0.1 ° | |
| Repeat accuracy | &le ± 0.1 ° | |
| Temperature influence | &le 0.027 °/K | |
| Functional safety related parameters | ||
| MTTFd | 300 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Teach-In indicator | 2 LEDs yellow (switching status), flashing | |
| Button | 2 push-buttons ( Switch points programming , Evaluation range programming ) | |
| Switching state | 2 yellow LEDs: Switching status (each output) | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | &le 25 mA | |
| Time delay before availability | &le 200 ms | |
| Switching output | ||
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected | |
| Operating current | &le 100 mA | |
| Voltage drop | &le 3 V | |
| Analog output | ||
| Output type | 1 current output 4 ... 20 mA | |
| Load resistor | 0 ... 200 &Omega at UB = 10 ... 18 V 0 ... 500 &Omega at UB = 18 ... 30 V | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 5 m, PUR cable 5 x 0.5 mm2 | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 2-axis | |
| Measurement range | 0 ... 360 ° | |
| Absolute accuracy | &le ± 0.5 ° | |
| Response delay | &le 25 ms | |
| Resolution | &le 0.1 ° | |
| Repeat accuracy | &le ± 0.1 ° | |
| Temperature influence | &le 0.027 °/K | |
| Functional safety related parameters | ||
| MTTFd | 300 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Teach-In indicator | 2 LEDs yellow (switching status), flashing | |
| Button | 2 push-buttons ( Switch points programming , Evaluation range programming ) | |
| Switching state | 2 yellow LEDs: Switching status (each output) | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | &le 25 mA | |
| Time delay before availability | &le 200 ms | |
| Switching output | ||
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected | |
| Operating current | &le 100 mA | |
| Voltage drop | &le 3 V | |
| Analog output | ||
| Output type | 2 current outputs 4 ... 20 mA (one output for each axis) | |
| Load resistor | 0 ... 200 &Omega at UB = 10 ... 18 V 0 ... 500 &Omega at UB = 18 ... 30 V | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 8-pin, M12 x 1 connector | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| Описание оборудования | ||
|---|---|---|
| Compact fire protection photoelectric sensor | ||
| General specifications | ||
|---|---|---|
| Signal type | Analog input | |
| Supply | ||
| Connection | Power Rail or terminals 14+, 15- | |
| Rated voltage | 20 ... 30 V DC | |
| Rated current | 75 mA | |
| Power dissipation | 1 W | |
| Power consumption | 2.25 W (typ. 1.68 W) | |
| Input | ||
| Connection side | field side | |
| Measurement range | terminals 1+, 3-: voltage 0/1 ... 5 V, load &ge 50 k&Omega or voltage 0/2 ... 10 V, load &ge 100 k&Omega terminals 2+, 3-: current 0/4 ... 20 mA load &le 50 &Omega | |
| Output | ||
| Connection side | control side | |
| Output I, II | terminals 7, 8, 9 10, 11, 12 | |
| Contact loading | 250 V AC / 4 A / cos &phi > 0.7 40 V DC / 2 A resistive load | |
| Output III | device configuration : terminals 4, 5, 6 | |
| Transfer characteristics | ||
| Deviation | &le 1 % | |
| Input delay | 100 ms | |
| Indicators/settings | ||
| Display elements | LEDs | |
| Control elements | DIP-switch potentiometer | |
| Configuration | via DIP switches via potentiometer | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Insulation coordination | EN 50178 | |
| Galvanic isolation | EN 50178 | |
| Degree of protection | IEC 60529 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 120 g | |
| Dimensions | 20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) , housing type B2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| General specifications | ||
|---|---|---|
| Measuring method | The tuning fork is brought to its resonance frequency by means of a piezoelectric drive. If the tuning fork is covered by liquid, this frequency changes. The electronics monitor the resonance frequency and indicate whether the tuning fork is freely vibrating or is covered by liquid. | |
| Construction type | compact device device with short tube | |
| Operating mode | MAX = maximum safety: The device keeps the electronic switch closed as long as the liquid level is below the fork. example application: overspill protection MIN = minimum safety: The device keeps the electronic switch closed as long as the fork is immersed in liquid. example application: dry running protection of pumps The electronic switch opens if the limit is reached, if a fault occurs or in the event of a power fails (quiescent current principle) | |
| Supply | ||
| Rated voltage | - DC-PNP: 10 ... 35 V DC, 3-wire - AC/DC: 20 ... 253 V AC/DC, 2-wire | |
| Current consumption | - DC-PNP: < 15 mA - AC/DC: < 3.8 mA | |
| Input | ||
| Measured variable | density | |
| Measurement range | min. 0.7 g/cm3, optional> 0.5 g/cm3 | |
| Output | ||
| Output type | switch output | |
| Switching current | max. 250 mA | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006 | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Electromagnetic compatibility | NE 21 | |
| Degree of protection | IEC 60529 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-64 | |
| Climate class | DIN EN 60068-2-38/IEC 68-2-38 | |
| Measurement accuracy | ||
| Reference operating conditions | - ambient temperature: 25 °C (+77 °F) - process pressure: 1 bar (14.5 psi) - fluid: water (density: approx. 1 g/cm3, viscosity: 1 mm2/s) - medium temperature: 25 °C (+77 °F) - density setting: > 0.7 g/cm3 - switching time delay: standard (0,5 s, 1 s) | |
| Measured value resolution | < 0.5 mm | |
| Measuring frequency | approx. 1100 Hz in air | |
| Switching point | 13 mm ± 1 mm | |
| Non-repeatability | ± 1 mm acc. to DIN 61298-2 | |
| Hysteresis | max. 3 mm | |
| Influence of ambient temperature | negligible | |
| Influence of medium temperature | -25 µm/°C | |
| Influence of medium pressure | -20 µm/bar | |
| Switching time | - 0.5 s when tuning fork is covered - 1.0 s when tuning fork is uncovered - other switching times on request | |
| Operating conditions | ||
| Installation conditions | ||
| Installation position | see section mounting position | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Shock resistance | a = 300 m/s2 = 30 g, 3 planes x 2 directions x 3 shocks x 18 ms, as per test Ea | |
| Vibration resistance | a(RMS) = 50 m/s2, ASD = 1.25 (m/s2)2/Hz, f = 5 to 2000 Hz, t = 3 x 2 h | |
| Process conditions | ||
| Medium temperature | -40 ... +100 °C (-40 ... +212 °F) -40 ... +150 °C (-40 ... +302 °F) | |
| Process pressure (static pressure) | -1 ... +40 bar (-14.5 ... +580 psi) | |
| State of aggregation | liquid | |
| Density | min. 0.7 g/cm3, optional> 0.5 g/cm3 | |
| Viscosity | 1 ... 10000 mPa/s, dynamic viscosity | |
| Solid contents | < &empty5 mm | |
| Mechanical specifications | ||
| Degree of protection | - IP65/67, NEMA 4X enclosure (plug M12) - IP65, NEMA 4X enclosure (valve plug) - IP65/68, NEMA 4X/6P enclosure (cable) | |
| Connection | - cable 5 m - valve plug NPT1/2 - valve plug QUICKON - valve plug M16 - plug M12 | |
| Material | see technical information (TI) | |
| Surface quality | Ra < 3.2 µm | |
| Mass | see technical information (TI) | |
| Dimensions | see technical information (TI) | |
| Process connection | - thread ISO 228 G1/2, G3/4, G1 - thread EN 10226 R1/2, R3/4, R1 - thread ASME MNPT1/2, MNPT3/4, MNPT1 | |
| Certificates and approvals | ||
| Overspill protection | Z-65.11-554 (overspill protection acc. to WHG) Z-65.40-555 (leak detection system acc. to WHG) If you need the approvals also in paper form, select the option WH in the type code. | |
| Accessories | ||
| Designation | see technical information (TI) | |
| General specifications | ||
|---|---|---|
| Measuring method | A metal plate at the end of the probe, within the insulation, and the surroundings (e. g. the silo walls) combine to form the two electrodes of a capacitor. If the probe is covered or free of material, then the capacitance changes and the LCL switches. | |
| Equipment architecture | The measuring system consists of: - the device - a supply point - the connected control systems, switching units, signalling systems (e. g. lamps, horns, PCS, PLC, etc.) | |
| Construction type | device with rod probe | |
| Operating mode | MAX = maximum safety: The device switches if the probe is covered or if the supply voltage is disconnected in a safety-oriented manner (signal on alarm). example application: overspill protection MIN = minimum safety: The device switches if the probe is uncovered or if the supply voltage is disconnected in a safetyoriented manner (signal on alarm). example application: dry-running protection | |
| Supply | ||
| Rated voltage | electrical connection E5: 10.8 ... 45 V DC, short-term pulse on 55 V DC electrical connection WA: 20 ... 235 V AC, 50/60 Hz or 20 ... 55 V DC | |
| Current consumption | electrical connection E5: max. 30 mA, reverse-polarity-proof electrical connection WA: max. 130 mA | |
| Electrical specifications | ||
| Surge protection | overvoltage category III | |
| Input | ||
| Measured variable | limit level (limit value) | |
| Measurement range | dielectric constant &ge 1.6 | |
| Output | ||
| Output signal | connection E5: switching PNP, Imax = 200 mA - overload and short circuit protection - residual voltage at transistor at Imax < 2.9 V connection WA: contact change-over, potential-free - Umax = 253 V - Imax = 4 A (AC) - Pmax = 1000 VA, cos &phi = 1, Pmax = 500 VA, cos &phi > 0.7 | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006 | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Electromagnetic compatibility | NE 21 | |
| Degree of protection | IEC 60529:2001 | |
| Vibration resistance | EN 60068-2-64 | |
| Climate class | EN 60068, part 2-38 (test Z/AD) | |
| Measurement accuracy | ||
| Reference operating conditions | vessel type: plastic vessel, ambient temperature: 73 °F (23 °C, 296 K), medium temperature: 73 °F (23 °C, 296 K) medium pressure pe: 0 bar, medium: dielectric constant = 2.6, conductivity: < 1 µS sensitivity setting: C | |
| Hysteresis | horizontal 4 mm (0.16 inch), vertical 7 mm (0.28 inch) | |
| Long-term drift | horizontal 3 mm (0.12 inch), vertical 6 mm (0.24 inch) | |
| Influence of medium temperature | depending on the filling material | |
| Switching time | approx. 0.5 s when covering and uncovering the sensor | |
| Operating conditions | ||
| Installation conditions | ||
| Installation position | any position | |
| Mounting location | The capacitive limit switch can be installed in silos made of different materials (e. g. metal, plastic, concrete). | |
| Process conditions | ||
| Process temperature | -40 ... 130 °C (-40 ... 266 °F) -40 ... 80 °C (-40 ... 176 °F) (Dust-Ex version) | |
| Medium pressure limits | -1 ... 25 bar | |
| State of aggregation | fluids and solids | |
| Solid contents | &le &empty 30 mm | |
| Bulk density | &le 200 g/l | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 80 °C (-40 ... 176 °F) -40 ... 60 °C (-40 ... 140 °F) (Dust-Ex version) | |
| Storage temperature | -40 ... 80 °C (-40 ... 176 °F) | |
| Shock resistance | device with F34 housing: 7 J | |
| Vibration resistance | a(RMS) = 50 m/s2, ASD = 1.25 (m/s2)2/Hz, f = 5 to 2000 Hz, t = 3 x 2 h | |
| Mechanical specifications | ||
| Degree of protection | IP66, NEMA 4 | |
| Connection | gland M20 thread G1/2, NPT1/2 | |
| Material | F14 housing: polyester PBT-FR F34 housing F34: aluminum Probe: PPS GF40 | |
| Dimensions | max. &empty94 mm (3.7 inch), length 391 mm (15.4 inch) | |
| Process connection | thread R1 acc. to EN 10226, BSPT, adapter for R1-1/2 and G1-1/2 see accessories thread NPT1 to ANSI B 1.20.1, adapter for NPT1-1/4 see accessories | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | see instruction manuals (SI) | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2009 | |
| Accessories | ||
| Optional accessories | LCL-Z10 cover with sight glass for F14 housing LCL-Z11 adapter for R1-1/2, EN 10226 LCL-Z12 adapter for G1-1/2, DIN ISO 228 LCL-Z13 adapter for NPT1-1/4, steel LCL-Z15 adapter for NPT1-1/4, 1.4571 | |
| General specifications | ||
|---|---|---|
| Equipment architecture | switching element: changeover switching on point: 15 mbar ± 3 mbar, switching off point: 9 mbar ± 3 mbar max. hydrostatic pressure: 500 mbar | |
| Supply | ||
| Rated voltage | 253 V AC , 50/60 Hz | |
| Current consumption | max. 1 A | |
| Conformity | ||
| Degree of protection | IEC 60529:2001 | |
| Operating conditions | ||
| Process conditions | ||
| Process temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP54 | |
| Connection | flat plug 6.3 x 0.8 mm (0.25 x 0.03 inch), DIN 46244 | |
| Material | housing: PA pipe: stainless steel 1.4571/316Ti or PVC | |
| Dimensions | housing: 100 x 75 x 80 mm (4 x 3 x 3.1 inch) pipe: length L 180 ... 5000 mm (0.6 ... 16.5 ft) | |
| Process connection | thread G1/2 to ISO 228 | |
| Описание оборудования | ||
|---|---|---|
| Sheet inspection sensor for monitoring print by comparing stored images or barcode evaluation | ||
| Описание оборудования | ||
|---|---|---|
| Laser light sensor for profile matching | ||
| Описание оборудования | ||
|---|---|---|
| Miniature photoelectric sensor with plug-in style housing for mounting in 13 mm hole | ||
| Описание оборудования | ||
|---|---|---|
| Laser thru-beam sensor | ||
| Описание оборудования | ||
|---|---|---|
| Precision positioning on hole in the 70 mm x 70 mm housing | ||
| Описание оборудования | ||
|---|---|---|
| Precision positioning on hole in the 70 mm x 70 mm housing | ||
| Описание оборудования | ||
|---|---|---|
| Gland screw connection | ||
| General specifications | ||
|---|---|---|
| Measuring method | The device is a measuring system that functions according to the time-of-flight method. The distance from the reference point (process connection of the measuring device) to the product surface is measured. | |
| Construction type | device with rod probe device with rope probe | |
| Supply | ||
| Rated voltage | 11.5 ... 35 V DC, 2-wire 10.4 ... 48 V DC, 4-wire 90 ... 253 V AC, 50/60 Hz | |
| Input | ||
| Measured variable | distance between reference point and product surface | |
| Measurement range | rod probe: 4 m (13 ft) rope probe: 12 m (39 ft) | |
| Output | ||
| Output signal | 4 ... 20 mA 2 x 4 ... 20 mA | |
| Communication | 4 ... 20 mA HART (standard) PROFIBUS PA (option) | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006 | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Degree of protection | IEC 60529:2001 | |
| Measurement accuracy | ||
| Accuracy | digital: ±2 mm (0.08 inch) analog: 0.02 % sum of non-linearity, non-repeatability and hysteresis included in the maximum measured error | |
| Operating conditions | ||
| Process conditions | ||
| Process temperature | -20 ... 80 °C (-4 ... 176 °F) | |
| Process pressure (static pressure) | -1 ... 6 bar (-14.5 ... 87 psi) | |
| Dielectric constant | rod probe: DC &ge 1.6 rope probe: DC &ge 1.6 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 80 °C (-40 ... 176 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP68, NEMA 6P (24 hours in water 1.83 m (6 ft) deep) IP66, NEMA 4X | |
| Connection | gland M20 thread M20, G1/2, NPT1/2 device plug M12, 7/8 in | |
| Material | materials in contact with process : rod probe: 1.4404/316L rope probe: 1.4401/316 process connections: 1.4404/316L, PPS-GF40 process membran, seal: Viton | |
| Process connection | threads: G3/4, MNPT3/4 flanges: universal flange | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | see instruction manuals (SI) | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-1:2007 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 , EN 60079-31:2009 | |
| International approvals | ||
| IECEx approval | see instruction manuals (SI) | |
| Certificates and approvals | ||
| Overspill protection | see approval (ZE) | |
| Telecommunications | radio license FCC | |
| Accessories | ||
| Designation | see technical information (TI) | |
| General specifications | ||
|---|---|---|
| Measuring method | The tuning fork is brought to its resonance frequency by means of a piezoelectric drive. If the tuning fork is covered by liquid, this frequency changes. The electronics monitor the resonance frequency and indicate whether the tuning fork is freely vibrating or is covered by liquid. | |
| Construction type | compact device | |
| Operating mode | MAX = maximum safety: The device keeps the electronic switch closed as long as the liquid level is below the fork. example application: overspill protection MIN = minimum safety: The device keeps the electronic switch closed as long as the fork is immersed in liquid. example application: dry running protection of pumps The electronic switch opens if the limit is reached, if a fault occurs or in the event of a power fails (quiescent current principle) | |
| Supply | ||
| Connection | This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements. | |
| Rated voltage | 10 ... 35 V DC | |
| Fusing | external 500 mA slow | |
| Current consumption | < 15 mA | |
| Residual ripple | 5 V ss at 0 ... 400 Hz | |
| Input | ||
| Measured variable | density | |
| Measurement range | min. 0.7 g/cm3 | |
| Output | ||
| Output type | switch output | |
| Switching current | max. 250 mA | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006 | |
| Directive 2004/108/EC | EN 61326-1:2006 , EN 61326-2-3:2006 | |
| Conformity | ||
| Electromagnetic compatibility | NE 21 | |
| Degree of protection | IEC 60529 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-64 | |
| Climate class | DIN EN 60068-2-38/IEC 68-2-38 | |
| Measurement accuracy | ||
| Reference operating conditions | - ambient temperature: 25 °C (+77 °F) - process pressure: 1 bar (14.5 psi) - fluid: water (density: approx. 1 g/cm3, viscosity: 1 mm2/s) - medium temperature: 25 °C (+77 °F) - density setting: > 0.7 g/cm3 - switching time delay: standard (0,5 s, 1 s) | |
| Measured value resolution | < 0.5 mm | |
| Measuring frequency | approx. 1100 Hz in air | |
| Switching point | 13 mm ± 1 mm | |
| Non-repeatability | ± 1 mm acc. to DIN 61298-2 | |
| Hysteresis | max. 3 mm | |
| Influence of ambient temperature | negligible | |
| Influence of medium temperature | -25 µm/°C | |
| Influence of medium pressure | -20 µm/bar | |
| Switching time | - 0.5 s when tuning fork is covered - 1.0 s when tuning fork is uncovered | |
| Switch-on delay | max. 3 s | |
| Operating conditions | ||
| Installation conditions | ||
| Installation position | see technical information (TI) | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Shock resistance | a = 300 m/s2 = 30 g, 3 planes x 2 directions x 3 shocks x 18 ms, as per test Ea | |
| Vibration resistance | a(RMS) = 50 m/s2, ASD = 1.25 (m/s2)2/Hz, f = 5 to 2000 Hz, t = 3 x 2 h | |
| Process conditions | ||
| Medium temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Process pressure (static pressure) | -1 ... +40 bar (-14.5 ... +580 psi) | |
| State of aggregation | liquid | |
| Density | min. 0.7 g/cm3 | |
| Viscosity | 1 ... 10000 mPa/s, dynamic viscosity | |
| Solid contents | < &empty5 mm | |
| Mechanical specifications | ||
| Degree of protection | IP65/IP67 , NEMA 4X | |
| Connection | M12 connector, 4-pin | |
| Material | process connection and short tube: stainless steel 316L (1.4401/1.4435) tuning fork: stainless steel 316L housing cover and connector: PPSU | |
| Surface quality | Ra < 3.2 µm | |
| Mass | approx. 140 g | |
| Process connection | thread G1/2 to ISO 228 | |
| Certificates and approvals | ||
| Overspill protection | see approval (ZE) | |
| Accessories | ||
| Designation | see technical information (TI) | |
Товаров: 0
На сумму: 0