Атол 30Ф не включается (заводской брак)
Валерий
14 января 2022
| Conformity | ||
|---|---|---|
| Degree of protection | IEC 60529 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 50 °C (-4 ... 122 °F) | |
| Storage temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP66 | |
| Connection | 1 cable gland M16 x 1.5 for cable diameter 5,5 ... 10 mm, blue color 1 M12 x 5 connector for connecting a barcode reader type PSCAN-D 1 PE bolt M6 | |
| Material | Housing: antistatic glass reinforced polyester, black color Holder for barcode reader: stainless steel 1.4301 (304) M12 cable gland: stainless steel 1.4301 (304) PE bolt: brass | |
| Mass | approx. 2000 g | |
| Dimensions | 155 x 145 x 217 mm | |
| Data for application in connection with hazardous areas | ||
| Statement of conformity | ||
| Group, category, type of protection, temperature class | simple apparatus for use in gas/dust atmosphere according to EN 60079-11, temperature class T4 | |
| Voltage | 30 V | |
| Current | 500 mA | |
| Power | 2 W | |
| General information | ||
| Supplementary information | Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| General specifications | ||
|---|---|---|
| Signal type | Analog input | |
| Supply | ||
| Connection | Power Rail or terminals 23+, 24- | |
| Rated voltage | 19 ... 30 V DC | |
| Rated current | approx. 120 mA at 24 V DC | |
| Power dissipation | 2.3 W | |
| Power consumption | 2.9 W | |
| HART signal channels (intrinsically safe) | ||
| Conformity | HART field device input (revision 5 to 7) | |
| Interface | ||
| Programming interface | programming socket | |
| Input | ||
| Connection side | field side | |
| Connection | terminals 1, 2, 3, 4, 5, 6 | |
| Open circuit voltage/short-circuit current | typ. 24 V / 28 mA | |
| Input resistance | 250 &Omega , 5 % (terminals 2, 3 and with jumper on 5, 6) | |
| Available voltage | &ge 15.5 V at 20 mA, short-circuit protected | |
| Output | ||
| Connection side | control side | |
| Connection | output I: terminals 7, 8, 9 , output II: terminals 13, 14, 15 , output III: terminals 19, 20, 21 | |
| Output signal | analog | |
| Current range | 4 ... 20 mA , (source or sink mode) | |
| Load | max. 650 &Omega , source mode | |
| Voltage range | 5 ... 30 V , sink mode from external supply | |
| Fault signal | downscale I &le 2 mA, upscale I &ge 21.5 mA (acc. NAMUR NE43) or hold measurement value | |
| Other outputs | HART communicator on terminals 22, 24 | |
| Collective error message | Power Rail and LED red | |
| Indicators/settings | ||
| Display elements | LEDs , display | |
| Control elements | Control panel | |
| Configuration | via operating buttons via PACTware | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2006 | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | 300 g | |
| Dimensions | 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C3 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | BASEEFA 07 ATEX 0174 | |
| Marking | II (1)GD [Ex ia] IIC, [Ex iaD] | |
| Certificate | PF 07 CERT 1142 X | |
| Marking | II 3G Ex nA II T4 X | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 | |
| International approvals | ||
| FM approval | ||
| Control drawing | 116-0129 | |
| IECEx approval | ||
| IECEx certificate | IECEx BAS 07.0047 | |
| IECEx marking | [Ex ia] IIC , [Ex iaD] | |
| General specifications | ||
|---|---|---|
| Signal type | Analog input | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 2 | |
| Supply | ||
| Connection | Power Rail or terminals 11+, 12- | |
| Rated voltage | 20 ... 35 V DC | |
| Ripple | within the supply tolerance | |
| Power dissipation | 0.5 W | |
| Power consumption | 0.6 W | |
| Input | ||
| Connection side | field side | |
| Connection | terminals 4-, 5-, 3+, 2+, 1+ | |
| Potentiometer | ||
| Types of measuring | 3-, 4-, 5-wire technology | |
| Lead resistance | 5 % of the potentiometer resistance (adjustable) | |
| Output | ||
| Connection side | control side | |
| Connection | terminals 7-, 8+ | |
| Voltage output | 0 ... 10 V | |
| Output resistance | max. 30 &Omega | |
| Transfer characteristics | ||
| Accuracy | 0.05 % | |
| Rise time | 10 to 90 % &le 8 ms 10 to 90 % within 1 % of span &le 25 ms | |
| Indicators/settings | ||
| Control elements | potentiometer | |
| Configuration | via potentiometer | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2006 | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 120 g | |
| Dimensions | 20 x 107 x 115 mm (0.8 x 4.2 x 4.5 inch) , housing type B1 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | BAS 00 ATEX 7171 | |
| Marking | II (1)G [Ex ia Ga] IIC , II (1)D [Ex ia Da] IIIC , I (M1) [Ex ia Ma] I (-20 °C &le Tamb &le 60 °C) | |
| Certificate | TÜV 02 ATEX 1797 X | |
| Marking | II 3G Ex nA II T4 | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 | |
| International approvals | ||
| FM approval | ||
| Control drawing | 116-0129 | |
| UL approval | ||
| Control drawing | 116-0173 (cULus) | |
| CSA approval | ||
| Control drawing | 116-0132 | |
| IECEx approval | IECEx BAS 10.0060 IECEx BAS 10.0061X | |
| Approved for | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I Ex nA II T4 Gc | |
| Описание оборудования | ||
|---|---|---|
| Current output 0/4 mA ... 20 mA | ||
| Описание оборудования | ||
|---|---|---|
| Current output 0/4 mA ... 20 mA | ||
| Supply | ||
|---|---|---|
| Rated voltage | 3.6 V DC , battery operated | |
| Power dissipation/power consumption | < 0.09 W | |
| Input | ||
| Connection | terminals 1, 2, 3, 4 | |
| RTD | type Pt100, Pt1000 (IEC 751: 1995 GOST: alpha = 0.391) | |
| Connection | 2-wire: 2 sensors, 3- or 4-wire: 1 sensor | |
| Lead resistance | max. 10 &Omega | |
| Measuring circuit monitoring | sensor breakage | |
| Thermocouples | type E, J, K, T (IEC 584-1) | |
| Cold junction compensation | internal , external | |
| Measuring circuit monitoring | sensor breakage | |
| Measurement range | type K: -270 ... 1370 °C type T: -270 ... 400 °C type E: -270 ... 1000 °C type J: -210 ... 1200 °C | |
| Resistor | ||
| Measurement range | 0 ... 500 &Omega , 0 ... 4000 &Omega | |
| Voltage | mV Input | |
| Measurement range | -100 ... 100 mV , 0 ... 300 mV | |
| Input resistance | &ge 1 M&Omega | |
| Output | ||
| Output variables | PV: input 1 (°C, &Omega, mV) SV: input 2 (°C, &Omega, mV) TV: CJC temperature (°C) estimated battery life (days) battery voltage (volts) residual battery capacity (%) | |
| Transfer characteristics | ||
| Accuracy | - internal cold junction compensation error ± 1,5 °C (typ. acc. to IEC 61298-3) - external cold junction compensation error ± 1 °C (typ.) - resolution error < 0.1 °C - accuracy TC ± 20 µV - accuracy RTD: ± 100 m&Omega | |
| Indicators/settings | ||
| Parameter assignment | - sampling period: 1, 2, 5, 10, 30 seconds or 1, 2, 5, 10, 30, 60 minutes - transmit power: configurable 0 dBm or 10 dBm (EIRP) - sensor type - mapping of input measuring values 1 and 2 into primary variable (PV) and secondary variable (SV) - publishing of up to three messages from the device, transmission rate selectable from 4 seconds to 60 minutes | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2004/108/EC | EN 61326-1:2006 | |
| Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. | |
| Directive 99/5/EC | ETSI EN 300328: V1.7.1 (2006-10), ETSI EN 301489-17: V1.2.1 (2002-08), EN 60950:2001 | |
| FCC CFR47 Part 15 B and C | ANSI C63.4-2003 | |
| Conformity | ||
| Degree of protection | IEC 60529 | |
| Accuracy | IEC 61298-3 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 test setup and execution acc. to EN 60068-2-60 | |
| Mechanical specifications | ||
| Degree of protection | IP65 | |
| Mass | approx. 1000 g | |
| Dimensions | 77 x 129 x 177 mm (3 x 5.08 x 6.97 inch) | |
| Mounting | panel or pole mounting | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | IMQ 09 ATEX 008X | |
| Group, category, type of protection | II 2(1)G Ex ia [ia] IIC T4 | |
| Directive conformity | ||
| Directive 94/9/EC | EN 60079-0:2006, EN 60079-11:2007, EN 60079-26:2007 | |
| International approvals | ||
| FM approval | CoC 3042534 | |
| IECEx approval | IECEx INE 09.0025X | |
| Approved for | Ex ia IIC T4 | |
| Accessories | ||
| Designation | battery W-BAT-B1-Li mandatory for use in connection with hazardous areas (order separately) Mounting set W-ACC-F7MK External cold junction compensation W-ACC-CJC | |
| Описание оборудования | ||
|---|---|---|
| Industrial Box Thin Client | ||
| General specifications | ||
|---|---|---|
| Signal type | Digital Output | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 3 | |
| Performance level (PL) | PL e | |
| Supply | ||
| Rated voltage | loop powered | |
| Power dissipation | < 1.3 W | |
| Power consumption | < 1.3 W | |
| Input | ||
| Connection side | control side | |
| Connection | Input terminals 5, 6 test input terminals 7, 8, 9, 10 | |
| Pulse/Pause ratio | 150 ms / 150 ms | |
| Signal level | 0-signal: -5 ... 5 V 1-signal: 19 ... 26.5 V | |
| Rated current | 0-signal: typ. 1.6 mA at 1.5 V typ. 8 mA at 3 V (maximum leakage current DO card) 1-signal: &ge 36 mA (minmum load current DO card) | |
| Output | ||
| Connection | terminals 1, 2 | |
| Contact loading | 253 V AC/3 A/cos &phi 0.7 30 V DC/3 A resistive load | |
| Minimum switch current | 10 mA / 24 V DC | |
| Energized/De-energized delay | 150 ms / 150 ms | |
| Mechanical life | 5 x 106 switching cycles | |
| Transfer characteristics | ||
| Switching frequency | < 3 Hz | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Machinery Directive | ||
| Directive 2006/42/EC | EN 62061:2005+AC:2010+A1:2013+A2:2015 , EN/ISO 13849-1:2015 | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2012 | |
| Degree of protection | IEC 60529:2013 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) Observe the temperature range limited by derating, see section derating. | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Mass | approx. 100 g | |
| Dimensions | 12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| Certificate | PF 15 CERT 3932 X | |
| Marking | II 3G Ex nC ec IIC T4 Gc [device in zone 2] | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-7:2015 , EN 60079-15:2010 | |
| General specifications | ||
|---|---|---|
| Signal type | Digital Output | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 3 | |
| Supply | ||
| Rated voltage | loop powered | |
| Power dissipation | 0.8 W | |
| Input | ||
| Connection side | control side | |
| Connection | terminals 7, 8, 9 | |
| Input current | &le 21 mA per channel | |
| Output | ||
| Safety note | Attention! Combination of output Ex i with output not Ex i is not permitted. If load voltage > 50 V, de-energize before removing the terminals. | |
| Connection side | field side | |
| Connection | terminals 1, 2, 3 4, 5, 6 | |
| Contact loading | 230 V AC/2 A/cos &phi > 0.7 40 V DC/2 A resistive load | |
| Energized/De-energized delay | approx. 10 ms / approx. 5 ms | |
| Mechanical life | 5 x 106 switching cycles | |
| Transfer characteristics | ||
| Switching frequency | < 10 Hz | |
| Indicators/settings | ||
| Display elements | LEDs | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2006 | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 100 g | |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | DMT 00 ATEX E 016 | |
| Marking | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
| Certificate | TÜV 00 ATEX 1621 X | |
| Marking | II 3G Ex nA nC IIC T4 | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 | |
| International approvals | ||
| FM approval | ||
| Control drawing | 116-0261 | |
| CSA approval | ||
| Control drawing | 116-0156 | |
| IECEx approval | IECEx BVS 10.0025 | |
| Approved for | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I | |
| Mechanical specifications | ||
|---|---|---|
| Thread type | metric ISO pitch 1.5 mm | |
| Thread size (TD) | M20 | |
| Degree of protection | IP66 | |
| Material | brass, nickel-plated | |
| O-Ring | silicone | |
| Mass | 50 g | |
| Dimensions | ||
| Width across corners (D2) | 27.5 mm | |
| Outer diameter (DO) | 17 inch | |
| Length outside enclosure (H) | 16 mm | |
| Width across flats (SW1) | 25 mm | |
| Width across flats (SW2) | 25 mm | |
| Thread length (TL) | 15 mm | |
| Total length (L) | 31 mm | |
| Tightening torque | ||
| Nut torque at enclosure (SW1) | 2 Nm | |
| Nut torque 2 (SW2) | 2 Nm | |
| Ambient conditions | ||
| Ambient temperature | -60 ... 85 °C (-76 ... 185 °F) | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | IMQ 13 ATEX 030X | |
| Marking | II 2 GD Ex e IIC Gb Ex tb IIIC Db | |
| International approvals | ||
| IECEx approval | IECEx IMQ 14.0003X | |
| Conformity | ||
| Degree of protection | EN 60079-0 | |
| General information | ||
| Delivery quantity | 1 | |
| Scope of delivery | Breather Drain, Metal washer gasket locknut brief instructions | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Mechanical specifications | ||
|---|---|---|
| Material | 6061 aluminum with clear anodized coating | |
| Mass | 0.564 kg | |
| Electrical specifications | ||
|---|---|---|
| Operating voltage | 220 ... 254 V 50/60 Hz | |
| Operating current | 0.15 A max. | |
| Terminal capacity | 2.5 mm2 | |
| Lamps | incandescent | |
| Power | 15 W | |
| Lampholder | SBC type | |
| Mechanical specifications | ||
| Height | 158 mm | |
| Width | 90 mm | |
| Depth | 73 mm | |
| Cover fixing | threaded joint | |
| Degree of protection | IP65 | |
| Cable entry | metric threaded | |
| Number of cable entries | 1 x M20 position A 1 x M20 position A fitted with Ex d sealing plug | |
| Material | ||
| Enclosure | cast iron | |
| Glass | toughened glass | |
| Glass color | white | |
| Finish | cast iron: painted black | |
| Seal | nitrile O-ring | |
| Mass | approx. 2 kg | |
| Mounting | 6.9 mm thru-holes | |
| Grounding | internal & external brass grounding terminals on base | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | SIRA 02 ATEX 1058 | |
| Marking | II 2 GD Ex d IIB T5 Gb, Ex tb IIIC T100°C Db ( ta ... +50°C ) Ex d IIB T4 Gb, Ex tb IIIC T135°C Db ( ta ... +85°C ) | |
| International approvals | ||
| IECEx approval | IECEx SIR 09.0117 | |
| Conformity | ||
| Degree of protection | EN 60529 | |
| General information | ||
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Electrical specifications | ||
|---|---|---|
| Operating voltage | 660 V DC / 1000 V AC max. | |
| Operating current | 1600 A max. | |
| Mechanical specifications | ||
| Enclosure cover | detachable , optional hinges | |
| Cover fixing | Stainless steel hexagonal head screws | |
| Degree of protection | IP66 (IP67 with O-ring) | |
| Cable entry | see PDF data sheet | |
| Defined entry area | see PDF data sheet | |
| Material | ||
| Enclosure | Aluminum alloy | |
| Finish | painted grey | |
| Mass | see PDF data sheet | |
| Mounting | see PDF data sheet | |
| Ambient conditions | ||
| Ambient temperature | see PDF data sheet | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | ||
| Group, category, type of protection, temperature class | [Ex] II 2 GDEx d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
| International approvals | ||
| IECEx approval | IECEx INE 14.0029X | |
| Conformity | ||
| Degree of protection | EN60529 | |
| General information | ||
| Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Electrical specifications | ||
|---|---|---|
| Operating voltage | 250 V AC max. | |
| Operating current | 16 A max. | |
| Mechanical specifications | ||
| Enclosure cover | fully detachable , concealed hinges | |
| Cover fixing | M6 stainless steel hexagon head screws , optional quarter-turn key locks | |
| Degree of protection | IP66 | |
| Cable entry | cable glands as per specification | |
| Gland plate on face(s) | see PDF data sheet | |
| Defined entry area | see PDF data sheet | |
| Material | ||
| Enclosure | 1.5 mm 316L, (1.4404) stainless steel | |
| Gland plate | 3 mm 316L, (1.4404) stainless steel | |
| Finish | electropolished | |
| Seal | one piece closed cell neoprene | |
| Mass | see PDF data sheet | |
| Dimensions | see PDF data sheet | |
| Mounting | see PDF data sheet | |
| Grounding | M10 internal/external brass grounding bolt through enclosure body | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) -50 °C (-58 °F) on request | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
| Marking | II 2 GD Ex db eb mb IIC T* Gb Ex ib IIC T* Gb Ex db eb ib mb IIC T* Gb T6/T80 °C @ Ta +40 °C T4/T130 °C @ Ta +55 °C | |
| International approvals | ||
| IECEx approval | IECEx CML 16.0008X | |
| INMETRO | TÜV 13.1665X | |
| EAC approval | TC RU C-DE.GB06.B.00567 | |
| Conformity | ||
| Degree of protection | EN60529 | |
| General information | ||
| Ordering information | This device will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Accessories | ||
| Optional accessories | see PDF data sheet | |
| Supply | ||
|---|---|---|
| Rated voltage | 20 ... 30 V DC | |
| Fusing | 3.15 A , 5 x 20 mm (0.2 x 0.8 inch) | |
| Power dissipation | 0.7 W , with Multiplexer | |
| Reverse polarity protection | yes | |
| HART signal channels (intrinsically safe) | ||
| HART signal channels | ||
| Number of channels | 32 unbalanced signal loops | |
| Redundancy | ||
| Supply | yes | |
| Galvanic isolation | ||
| HART signal channels | 30 V DC | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 55 °C (-4 ... 131 °F) | |
| Relative humidity | 5 ... 90 %, non-condensing | |
| Mechanical specifications | ||
| Core cross-section | 2.5 mm2 (16 AWG) | |
| Connection | field side: fixed screw terminals control side: fixed screw terminals RS 485 interface: removable screw terminals power: removable screw terminals | |
| Mass | approx. 500 g | |
| Dimensions | without HiDMux2700: 222 x 122 x 79 mm (8.7 x 4.8 x 3.1 inch) with HiDMux2700: 222 x 122 x 208 mm (8.7 x 4.8 x 8.2 inch) | |
| Mounting | DIN rail mounting | |
| Supply | ||
|---|---|---|
| Connection | X20: terminals 3, 5 (+) 4, 6 (-) | |
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 2 A , in each case for 8 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Error message output | ||
| Connection | X20: terminals 1, 2 | |
| Output type | volt-free contact | |
| Contact loading | 30 V AC/40 V DC, 2 A | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (Termination Board power supply) - LED power supply I, green LED - LED power supply II, green LED LED FAULT (fault indication), red LED - LED lits: module failure - LED flashes: power supply failure | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description. | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): screw terminals, blue safe area connection (control side): IDC plug, 16-pin power supply connection: pluggable screw terminals, black | |
| Core cross-section | 0.25 ... 1.5 mm2 (24 ... 12 AWG) | |
| Material | housing: polycarbonate, 10 % glass fiber reinforced | |
| Mass | approx. 600 g | |
| Dimensions | 150 x 200 x 163 mm (5.9 x 7.9 x 6.42 inch) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-26:2007 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | see control drawing of correspoding modules | |
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I | |
| General specifications | ||
|---|---|---|
| Sensing range | 0.3 ... 4 m , with fluids | |
| Transducer frequency | approx. 85 kHz | |
| Indicators/operating means | ||
| LED green | Power on | |
| LED red | 2 Hz flashing: error | |
| Electrical specifications | ||
| Operating voltage | 20 ... 30 V DC , ripple 10 %SS | |
| Power consumption | &le 1200 mW | |
| Output | ||
| Output type | 1 analog output 4 ... 20 mA, RL &le 500 Ohm, error &ge 21 mA 1 voltage output 0 ... 10 V, RL &ge 1000 Ohm, error &ge 10.5 V | |
| Resolution | 2 mm | |
| Deviation of the characteristic curve | 0.5 % of upper limit of measuring range | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP65 | |
| Connection | 5-pin V15 (M12 x 1) connector | |
| Material | ||
| Housing | PBT, polypropylene | |
| Transducer | PTFE (diaphragm surface) | |
| Mass | 220 g | |
| Mounting | G1½A connection | |
| Slots | ||
|---|---|---|
| Occupied slots | 1 | |
| Supply | ||
| Connection | backplane bus | |
| Rated voltage | 12 V DC , only in connection with the power supplies LB9*** | |
| Power dissipation | 2 W | |
| Power consumption | 3 W | |
| Internal bus | ||
| Connection | backplane bus | |
| Interface | manufacturer-specific bus to standard com unit | |
| Analog input | ||
| Number of channels | 4 | |
| Suitable field devices | ||
| Field device | pressure converter | |
| Field device [2] | flow converter | |
| Field device [3] | level converter | |
| Field device [4] | Temperature Converter | |
| Field device interface | ||
| Connection | 2-wire transmitter | |
| Connection | terminals 1+, 2- 3+, 4- 5+, 6- 7+, 8- | |
| Transmitter supply voltage | min. 15 V at 20 mA 21.5 V at 4 mA | |
| Input resistance | 15 &Omega | |
| Line fault detection | can be switched on/off for each channel via configuration tool , configurable via configuration tool | |
| Short-circuit | factory setting: > 21 mA Can be parameterized in the range 0 ... 22 mA | |
| Open-circuit | factory setting: < 3.6 mA Can be parameterized in the range 0 ... 22 mA | |
| HART communication | yes | |
| HART secondary variable | yes | |
| Analog output | ||
| Number of channels | 4 | |
| Suitable field devices | ||
| Field device | Proportional Valve | |
| Field device [2] | I/P converters | |
| Field device [3] | on-site display | |
| Connection | terminals 1+, 2- 3+, 4- 5+, 6- 7+, 8- | |
| Line fault detection | can be switched on/off for each channel via configuration tool , configurable via configuration tool | |
| Short-circuit | factory setting: < 50 &Omega configurable between 0 ... 26 mA | |
| Open-circuit | deviation of preset output value > 0.5 mA | |
| Load | 750 &Omega max. | |
| HART communication | yes | |
| HART secondary variable | yes | |
| Watchdog | output off 0.5 s after serious fault | |
| Digital input | ||
| Number of channels | 4 | |
| Sensor interface | ||
| Connection [2] | volt-free contact | |
| Connection | terminals 1+, 2- 3+, 4- 5+, 6- 7+, 8- | |
| Digital signals (active) | ||
| Switching point: ON | > 2.1 mA | |
| Switching point: OFF | < 1.2 mA | |
| Line fault detection | can be switched on/off for each channel via configuration tool | |
| Connection | mechanical switch with additional resistors (see connection diagram) | |
| Short-circuit | > 7 mA | |
| Open-circuit | < 0.1 mA | |
| Digital output | ||
| Number of channels | 4 | |
| Suitable field devices | ||
| Field device | Solenoid Valve | |
| Field device [2] | audible alarm | |
| Field device [3] | visual alarm | |
| Connection | terminals 1+, 2-, 3+, 4-, 5+, 6-, 7+, 8- | |
| Drive capability | 12 V / 22 mA | |
| Open loop voltage | min. 22.7 V | |
| Current limit | 22 mA | |
| Internal resistor | 385 &Omega | |
| Line fault detection | can be switched on/off for each channel via configuration tool | |
| Test current | 0.4 mA | |
| Short-circuit | < 50 &Omega | |
| Open-circuit | < 0.2 mA | |
| Transfer characteristics | ||
| Deviation | ||
| After calibration | 0.1 % of the signal range at 20 °C (68 °F) | |
| Refresh time | approx. 100 ms (4 channels) | |
| Indicators/settings | ||
| LED indicator | Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1-4) red: line fault (lead breakage or short circuit) , yellow: state of digital I/O (0/1) Configuration LED (AI, AO, DI, DO) white: selected channel mode | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2006 | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2007 | |
| Degree of protection | IEC 60529:2000 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex) | |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
| Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 | |
| Vibration resistance | frequency range 10 ... 150 Hz transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g 10 cycles frequency range 5 ... 100 Hz transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g 90 minutes at each resonance | |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
| Mechanical specifications | ||
| Degree of protection | IP20 (module) , mounted on backplane | |
| Connection | removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2) | |
| Mass | approx. 100 g | |
| Dimensions | 16 x 100 x 102 mm (0.63 x 3.9 x 4 inch) | |
| Data for application in connection with hazardous areas | ||
| Certificate | BVS 12 ATEX E 115 X | |
| Marking | II 3 G Ex nA [ic] IIC T4 Gc | |
| Galvanic isolation | ||
| Rated voltage | 250 V field circuits to control and supply circuits | |
| Input/power supply, internal bus | safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V | |
| Output/power supply, internal bus | safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2009 EN 60079-11:2007 EN 60079-15:2010 | |
| International approvals | ||
| ATEX approval | BVS 12 ATEX E 115 X | |
| IECEx approval | BVS 11.0068X | |
| Approved for | Ex nAc [ic] IIC T4 | |
| Marine approval | ||
| Lloyd Register | 15/20021 | |
| Bureau Veritas Marine | 22449/B0 BV | |
| General specifications | ||
|---|---|---|
| Design / Mounting | Cabinet installation | |
| Electrical specifications | ||
| Rated voltage | 33 V | |
| Rated current | 500 mA | |
| Voltage protection level | ||
| Line/Line | max. 58 V category C1/C2 8/20µsec max. 50 V category C3 1kV/µsec max. 51 V category B2 10/700µsec max. 55 V category D1 10/350µsec | |
| Line/Earth | max. 1400 V category C1/C2 8/20µsec max. 1100 V category C1/C2 1kV/µsec max. 1000 V category B2 10/700µsec max. 1300 V category D1 10/350µsec | |
| Screen/Shield directly grounded | max. 25 V category C1/C2 8/20µsec max. 20 V category D1 10/350µsec | |
| Screen/Shield indirectly grounded (via GDT) | max. 700 V category C1/C2 8/20µsec max. 600 V category C3 1kV/µsec max. 500 V category B2 10/700µsec max. 600 V category D1 10/350µsec | |
| Reaction time | ||
| Line/Line | max. 1 ns | |
| Line/Earth | max. 100 ns | |
| Screen/Shield-Earth | max. 100 ns | |
| Overstressed fault mode | acc. IEC 61643-21 line inoperable mode 3 lines 1 and 2 at 15,5kA (8/20µsec) lines 3 and 4 at 30kA (8/20µsec) | |
| Series resistance in line | 1 &Omega +/- 5 % | |
| Impulse durability | ||
| Per line | 1 kA category D1 10/350µsec , 5 kA category C1/C2 8/20µsec | |
| Screen/Shield directly grounded | 5 kA category D1 10/350µsec | |
| Screen/Shield indirectly grounded (via GDT) | 4 kA category D1 10/350µsec , 10 kA category C1/C2 8/20µsec | |
| Capacitance | ||
| Line/Line | 800 pF | |
| Line/Earth | 16 pF | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 | |
| Standard conformity | ||
| Degree of protection | IEC 60529 | |
| Fieldbus standard | IEC 61158-2 | |
| Climatic conditions | IEC 60721 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-6 | |
| Surge protection | IEC 61643-21 | |
| Ambient conditions | ||
| Ambient temperature | -50 ... 80 °C (-58 ... 176 °F) | |
| Storage temperature | -50 ... 85 °C (-58 ... 185 °F) | |
| Relative humidity | &le 95 % non-condensing | |
| Shock resistance | 15 g 11 ms | |
| Vibration resistance | 1 g , 10 ... 150 Hz | |
| Mechanical specifications | ||
| Connection type | screw terminals | |
| Core cross-section | flexible wire 2.5 mm2 solid wire max. 4 mm2 | |
| Housing material | Polyamide PA 6.6 | |
| Degree of protection | IP20 | |
| Mass | Protection Module 20 g , base module 40 g | |
| Mounting | 35 mm DIN mounting rail | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | KEMA 09 ATEX 0191 X | |
| Marking | II 2(1)G Ex ia [ia Ga] IIC T4/T5/T6 Gb | |
| Voltage | 30 V | |
| Current | 500 mA | |
| Internal capacitance | negligible 0 nF | |
| Internal inductance | negligible 0 µH | |
| Certificate | KEMA 09 ATEX 0190 X | |
| Marking | II 3G Ex ic IIC T4/T5/T6 Gc , II 3G Ex nA IIC T4/T5/T6 Gc | |
| Voltage | 33 V | |
| Current | 500 mA | |
| Internal capacitance | negligible 0 nF | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 | |
| International approvals | ||
| CSA approval | CSA 2437472 | |
| Control drawing | 116-0361 | |
| Approved for | Class I, Zone 1, AEx/Ex ia IIC T4...T6, Class I, Zone 2, AEx nC IIC T4...T6, Class I, Zone 2, Ex nL IIC T4...T6, Class I, Zone 2, AEx/Ex nA IIC T4...T6 Class I Div. 1, GP A, B, C, D T4...T6, Class I Div. 2, GP A, B, C, D T4...T6, Class I Div. 2, GP A, B, C, D T4...T6 | |
| IECEx approval | IECEx KEM 09.0088X | |
| Approved for | Ex ia [ia Ga] IIC T4/T5/T6 Gb , Ex ic IIC T4/T5/T6 Gc , Ex nA IIC T4/T5/T6 Gc | |
| Certificates and approvals | ||
| Marine approval | pending | |
| General specifications | ||
|---|---|---|
| Design / Mounting | Cabinet installation | |
| Electrical specifications | ||
| Rated voltage | 33 V | |
| Rated current | 500 mA | |
| Voltage protection level | ||
| Line/Line | max. 58 V category C1/C2 8/20µsec max. 50 V category C3 1kV/µsec max. 51 V category B2 10/700µsec max. 55 V category D1 10/350µsec | |
| Line/Earth | max. 1400 V category C1/C2 8/20µsec max. 1100 V category C1/C2 1kV/µsec max. 1000 V category B2 10/700µsec max. 1300 V category D1 10/350µsec | |
| Screen/Shield directly grounded | max. 25 V category C1/C2 8/20µsec max. 20 V category D1 10/350µsec | |
| Screen/Shield indirectly grounded (via GDT) | max. 700 V category C1/C2 8/20µsec max. 600 V category C3 1kV/µsec max. 500 V category B2 10/700µsec max. 600 V category D1 10/350µsec | |
| Reaction time | ||
| Line/Line | max. 1 ns | |
| Line/Earth | max. 100 ns | |
| Screen/Shield-Earth | max. 100 ns | |
| Overstressed fault mode | acc. IEC 61643-21 line inoperable mode 3 lines 1 and 2 at 15,5kA (8/20µsec) lines 3 and 4 at 30kA (8/20µsec) | |
| Series resistance in line | 1 &Omega +/- 5 % | |
| Impulse durability | ||
| Per line | 1 kA category D1 10/350µsec , 5 kA category C1/C2 8/20µsec | |
| Screen/Shield directly grounded | 5 kA category D1 10/350µsec | |
| Screen/Shield indirectly grounded (via GDT) | 4 kA category D1 10/350µsec , 10 kA category C1/C2 8/20µsec | |
| Capacitance | ||
| Line/Line | 800 pF | |
| Line/Earth | 16 pF | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 | |
| Standard conformity | ||
| Degree of protection | IEC 60529 | |
| Fieldbus standard | IEC 61158-2 | |
| Climatic conditions | IEC 60721 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-6 | |
| Surge protection | IEC 61643-21 | |
| Ambient conditions | ||
| Ambient temperature | -50 ... 80 °C (-58 ... 176 °F) | |
| Storage temperature | -50 ... 85 °C (-58 ... 185 °F) | |
| Relative humidity | &le 95 % non-condensing | |
| Shock resistance | 15 g 11 ms | |
| Vibration resistance | 1 g , 10 ... 150 Hz | |
| Mechanical specifications | ||
| Connection type | screw terminals | |
| Core cross-section | flexible wire 2.5 mm2 solid wire max. 4 mm2 | |
| Housing material | Polyamide PA 6.6 | |
| Degree of protection | IP20 | |
| Mass | Protection Module 20 g , base module 40 g | |
| Mounting | 35 mm DIN mounting rail | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | KEMA 09 ATEX 0191 X | |
| Marking | II 2(1)G Ex ia [ia Ga] IIC T4/T5/T6 Gb | |
| Voltage | 30 V | |
| Current | 500 mA | |
| Internal capacitance | negligible 0 nF | |
| Internal inductance | negligible 0 µH | |
| Certificate | KEMA 09 ATEX 0190 X | |
| Marking | II 3G Ex ic IIC T4/T5/T6 Gc , II 3G Ex nA IIC T4/T5/T6 Gc | |
| Voltage | 33 V | |
| Current | 500 mA | |
| Internal capacitance | negligible 0 nF | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 | |
| International approvals | ||
| CSA approval | CSA 2437472 | |
| Control drawing | 116-0361 | |
| Approved for | Class I, Zone 1, AEx/Ex ia IIC T4...T6, Class I, Zone 2, AEx nC IIC T4...T6, Class I, Zone 2, Ex nL IIC T4...T6, Class I, Zone 2, AEx/Ex nA IIC T4...T6 Class I Div. 1, GP A, B, C, D T4...T6, Class I Div. 2, GP A, B, C, D T4...T6, Class I Div. 2, GP A, B, C, D T4...T6 | |
| IECEx approval | IECEx KEM 09.0088X | |
| Approved for | Ex ia [ia Ga] IIC T4/T5/T6 Gb , Ex ic IIC T4/T5/T6 Gc , Ex nA IIC T4/T5/T6 Gc | |
| Certificates and approvals | ||
| Marine approval | pending | |
| General specifications | ||
|---|---|---|
| Device type | type 2 acc. to EN 61643-11 class II acc. to IEC 61643-1 | |
| Number of protected supply lines | 1 | |
| Suitable components | protection module M-LB-1.150.M | |
| Electrical specifications | ||
| Nominal voltage | 120 V AC | |
| Maximum continuous operating voltage | max. 150 V AC max. 200 V DC | |
| Temporary over-voltage | 175 V / 5 s (TOV withstand) | |
| Nominal discharge current (8/20 µs) | 15 kA | |
| Max. surge current (8/20 µs) | 40 kA | |
| Voltage protection level | max. 0.7 kV max. 0.55 kV at 5 kA | |
| Reaction time | max. 25 ns | |
| Short-circuit-proof | 50 kA eff | |
| Overcurrent protection | max. 125 A gG , mains-side | |
| Fault indication output | ||
| Connection | terminals 11, 12, 14 | |
| Output | volt-free change-over contact | |
| Switch power | AC: 250 V / 0.5 A DC: 250 V/0.1 A 125 V/0.2 A 75 V/0.5 A 24 V/0.5 A | |
| Indicators/settings | ||
| Display elements | status display operating state (green) fault indication (red) | |
| Directive conformity | ||
| Low voltage | ||
| Directive 2014/35/EU | EN 61643-11:2012 | |
| Conformity | ||
| Degree of protection | IEC 60529 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 80 °C (-40 ... 176 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Core cross-section | - min. 1.5 mm2 solid/flexible - max. 35 mm2 stranded/25 mm2 flexible - max. 1.5 mm2 solid/flexible (for remote signalling contact) | |
| Material | ||
| Housing | thermoplastic, color grey , UL 94 V-0 | |
| Mass | approx. 240 g | |
| Dimensions | 18 x 90 x 73 mm (0.7 x 3.6 x 2.9 inch) (1 TE acc. to DIN 43880) | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Описание оборудования | ||
|---|---|---|
| &lambda/4 surge protection, N socket to N socket | ||
| Описание оборудования | ||
|---|---|---|
| 24 V DC | ||
| Описание оборудования | ||
|---|---|---|
| 230 V AC | ||
| Описание оборудования | ||
|---|---|---|
| 24 V DC | ||
| Описание оборудования | ||
|---|---|---|
| 24 V DC | ||
| Описание оборудования | ||
|---|---|---|
| 48 V AC ... 253 V AC/20 V DC ... 90 V DC | ||
| Описание оборудования | ||
|---|---|---|
| 48 V AC ... 253 V AC/20 V DC ... 90 V DC | ||
| Supply | ||
|---|---|---|
| Rated voltage | 20 ... 30 V DC SELV/PELV | |
| Power consumption | < 5 W | |
| External bus | ||
| Connection | screw terminals for - 0.2 ... 4 mm2 (rigid wire) - 0.2 ... 2.5 mm2 (flexible wire) | |
| Interface 1 | Ethernet 10 BASE-T/100 BASE-TX , full galvanic isolation | |
| Protocol | HART UDP, MODBUS TCP | |
| Interface 2 | RS-485 | |
| Protocol | HART, MODBUS RTU | |
| Transfer rate | max. 115 kBit/s | |
| Galvanic isolation | ||
| Interface/interface | basic insulation according to IEC 61140, rated insulation voltage 50 Veff | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 | |
| Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. | |
| Directive 2014/53/EU | EN 300328: V2.1.1 EN 301489-17: V1.3.2 | |
| FCC CFR47 Part 15 B and C | ANSI C63.4-2003 | |
| Conformity | ||
| Degree of protection | IEC 60529 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 test setup and execution acc. to EN 60068-2-60 | |
| Mechanical specifications | ||
| Degree of protection | IP66/IP67 | |
| Mass | approx. 1 kg | |
| Dimensions | 258 mm x 114 mm x 84 mm without antenna and cable glands | |
| Mounting | panel mounting | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | FM 12 ATEX 0061 | |
| Marking | II 3 G Ex nA IIC T4 Gc | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 | |
| International approvals | ||
| FM approval | Coc3042646 | |
| Approved for | NI Class I, Div. 2, GPS A-D NI Class II, Class III, Div. 2, GPS E-G | |
| IECEx approval | IECEx FMG 12.0002 | |
| Approved for | Ex nA IIC T4 Gc , Ex nAc T4 | |
Товаров: 0